Features
• Easy installation with strip terminal
• Tight regulation: 0.05% Line; 0.05% Load
• Full Output Ratings to +50 o C
• Built in OVP on 5 Volt Outputs
• OVP Option for 12V, 15V and 24V
• Foldback Current Limiting Overload Protection
with Automatic Recovery
General Specifications
Voltage/Current Ratings
Model Numbers
SLS-05-120-1T
SLS-12-068T
SLS-15-060T
SLS-24-048T
0 to +50 o C (Derate to 40% at +70 o C)
Operating Temperature Range
+/- 0.01% / o C
Temperature Coefficient (Typical)
Stability
Within +/- 0.05% (24 hours after warm-up)
Vibration
Per MIL-STD-810C, Method 514
Shock
Per MIL-STD-810C, Method 516
EMI/RFI
Linear power supplies have inherently low conducted and radiated noise levels.
For most system applications, these power supplies will meet the requirements
of FCC Class "B" and VDE 0871 for Class "B" equipment without additional
noise filtering.
Cooling
Forced air. 20 CFM required for full rating Derate 30% for convection cooling.
Multi Input (all units)
100/120/220/230/240 VAC selectable +/- 10% except 230 VAC is +15%, -6%
Frequency Range
47-63 Hz (Typical is 60 Hz. Derate output 10% at 50 Hz)
Transient Response Time
50 µ at 50% load changes for outputs rated up to 6A
100 µ at 50% load changes for outputs rated 6A and over.
Fuse Requirements
Units are not fused internally. For safe operation, user must provide input line
fuse as per values given in table.
Line Regulation
0.05% for +/- 10% change
Load Regulation
0.05% for 50% change
Ripple
3.0 mV maximum peak-to-peak
DC Output Adjustment Range
+/- 5% minimum (Check Voltage & Current ADJ Placement Diagrams)
Overvoltage Protection
All 5 volt outputs include built-in OVP standard (setting is 6.2V +/- 0.4 V). OVP
is optionally available on other outputs
Remote Sensing
All units have remote sensing capability.
Overload Protection
125 to 150% foldback current limit
Linear Open Frame DC Power Supplies
Silver Line Instruction Manual
Models: SLS-05-120-1T, SLS-12-068T,
SLS-15-060T, SLS-24-048T
• Multi-Tap AC Inputs
• 100% Four-Hour Burn-in
• Limited Warranty for two years
• UL Recognized
• CSA Certified
• CE Marked
• CB Certified
Output (Volts)
Output (Amps)
5
12
15
24
Input Specifications
Output Specifications
OVP (OPTIONAL)
Input AC Connections (See Case I2)
. 512" (13)
For use
at:
100 VAC
120 VAC*
220 VAC
230 VAC
240 VAC
*Note: Unit is shipped for 120V input from factory.
. 473" (12)
Mechanical Dimensions: Inches (mm)
OVP (OPTIONAL)
. 512" (13)
12.0
6.8
. 75" (19)
6.0
4.8
. 473" (12)
. 75" (19)
5
1
3
2
4
AC Input
Case I1
5
1
3
2
4
AC Input
Note: T he DC output can be adjusted with V. ADJ.
Case I2
I. LIM is factory set on all models and should not be adjusted by users.
Application Note: U ser needs to provide earth ground to power supply with either solder to Tab or using washer and
AC INPUT/DC OUTPUT
9.00" (229)
8.00" (203)
Apply AC
Primary Fuse
Connect
to:
SLS-05-120-1T
1-3, 2-4
1 & 5
Please
2 A / 125 V
See
1-3, 2-4
1 & 4
2 A / 125 V
Voltage
&
2-3
1 & 5
1 A / 250 V
Current
ADJ
2-3
1 & 4
1 A / 250 V
Placement
Diagrams
2-3
1 & 4
1 A / 250 V
. 188"
(4.8 )
°
MTG HOLES (12 PLACES)
AC INPUT/DC OUTPUT
1.250" (32)
9.00" (229)
. 75" (19)
8.00" (203)
. 551" (14)
MAX
Please
See
Voltage
&
Current
ADJ
Placement
Diagrams
. 188"
(4.8 )
°
MTG HOLES (12 PLACES)
5
1
2
4
5
1
3
2
4
3
WEIGHT: 7. 5 LBS.
(3.4 KG)
AC Input
5V
12V
AC Input
12/15V
PEM NUT HOLES
8-32 MTG (4 PLACES)
Case I1
Case I3
5
1
3
2
4
5
1
3
2
4
5V
12V
AC Input
12/15V
12/15V
AC Input
Case I3
Case I2
5
1
3
2
4
Case I2
AC Input
Case I4
Case I4
nut assembly.
The SLS power supply is shipped from the factory with metal shorting straps connected between
the + OUT and + S terminals and the (-) OUT and (-) S terminals. This strapping configuration
allows the output of the SLS to be taken from either pair of terminals. This is the
standard configuration.
The remote sense feature is enabled by removing the shorting straps and connecting the
individual OUT and S terminals to the appropriate points of the load. If an OVP circuit is used it
should be connected to the + OUT and (-) OUT terminals. The OVP should never be connected
to the + S, - S terminals without the use of the shorting straps. In all cases it is critical that the
terminal screws be firmly tightened.
Contact Technical Services at 1-800-377-4384 or tech@sola-hevi-duty.com with any questions.
Visit our website at www.solaheviduty.com
1.250" (32)
. 75" (19)
Primary Fuse
. 551" (14)
Primary Fuse
MAX
SLS-15-060T
SLS-24-048T
SLS-12-068T
2.5 A / 125V
3.0A / 125V
2.5 A / 125V
3.0A / 125V
1.25A / 250V
1.5A / 250V
1.25A / 250V
1.5A / 250V
1.25A / 250V
1.5A / 250V
Voltage & Current
WEIGHT: 7. 5 LBS.
(3.4 KG)
ADJ Placement
Diagrams
PEM NUT HOLES
8-32 MTG (4 PLACES)
R12
V.ADJ
R5
I.LIM
SLS-05-120-1T
12/15V
R12
V.ADJ
R9
I.LIM
5
1
3
2
4
AC Input
SLS-12-068T
SLS-15-060T
SLS-24-048T