Infi nitely variable lift units
Maximum load
75 kg, incl. worktop.
Operation
When the infi nitely variable lift unit is fi tted in accordance
with the installation guide, the unit is ready for use.
Adjustment
Adjust the unit by slackening the screw. The unit can then be
set to the desired height. Retighten the screw.
Service inspection
We recommend that a service inspection is performed once
annually.
1.
Check the supports. Replace any broken supports.
Support the worktop and remove it from the support.
Detach the support from the wall bracket by unscrewing
and removing the bolt.
reverse sequence.
2.
Check the wall brackets and tighten if necessary.
Remove supports when tightening (including worktop)
from the wall bracket by unscrewing and removing
the bolts.
The wall brackets can now be tightened.
44
Replace the parts in reverse sequence.
Faultfi nding
Fault
Cause
Worktop not level.
The telescopic legs are not
mounted at the same height
(not level).
41
Fit a new support in the
43
42
45
Remedy
If the supports cannot be height
adjusted, check the threaded
insert mounted inside the
bracket. There must be no screw
heads in the way of the threaded
inset.
If the supports cannot be
secured at a given height, we
recommend adjusting the height
a little before trying again.
max
max
41
75 kg
75 kg
(165 lbs)
(165 lbs)
75 kg
(165 lbs)
(165 lbs)
42
43
43
44
45
Infi nitely variable lift units
max
max
75 kg
19