MANUALE D'INSTALLAZIONE E USO

DELAY START

WHAT IS IT? The delay start is the time in minutes (0-99min) after the power on, at the end of a Flow Alarm and at the
end of an O.R./U.R. signal, that DUAL waits for before dosing the chemical product or activating the CL power plug (on
DUAL pH/CL REG).. During this period of time the display shows the message "Del" on the second line alternativenly with
the measure (see figure here above). During this time of delay DUAL can't dose or activate the power plug (on DUAL
pH/CL REG ) but it is possible to enter the menu and modify the parameters and calibrations.
PH STABILITY
WHAT IS IT? It's a control that DUAL performs when it is switched on that allows the system to stabilize the pH before
dosing the chlorine or activating the CL power plug on DUAL pH/CL REG.
In fact, if pH stability is setted (Yes), at the power on, DUAL waits that the pH measure reaches the desired set point before
starting the programmed dosing on the CL.
However, there is an extra control that DUAL performs: if after 1 hour the pH doesn't stabilize, DUAL unlocks the dosage of
the CL.
The pH stability control is automatically excluded if pH or CL has been programmed in manual type.
Codice 1075262
Push and quickly release CAL button and then pressing + and – buttons
select the language choice "Language Selection". Push CAL to enter the
language submenu and select " English" by pressing + or - .
Push CAL to confirm the choice and ESC to go back to measuring.
DELAY START EDITING
Push and quickly release CAL button and scroll the menu using + and – buttons
till the display shows "Start Delay". Push CAL to enter the submenu and then,
by pushing + and – button, choose the value in minutes (0-99). Push CAL to
confirm and ESC to go back to measuring.
Please note that the change will take effect from the next power on of
DUAL!
pH STABILITY EDITING
Push and quickly release CAL button and scroll the menu using + and –
buttons till the display shows "pH Stability". Push CAL to enter the submenu
and then by pushing + and – button choose "Yes" if you want to program the
pH Stability control or "No" if you do not want to use it. Push CAL to confirm
and ESC to go back to measuring.
Please note that the change will take effect from the next power on of
DUAL!