INSTALLATION INSTRUCTIONS FOR IN-LINE DUCT FANS™
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INSTRUCTIONS
WARNING – RISK OF ELECTRIC SHOCK. CAN CAUSE INJURY OR DEATH: DISCONNECT AND/OR LOCKOUT ALL REMOTE ELECTRIC POWER
SUPPLIES BEFORE SERVICING OR INSTALLING. WHEN THE SERVICE DISCONNECTING MEANS CANNNOT BE LOCKED, SECURELY FASTEN A
PROMINENT WARNING DEVICE, SUCH AS A TAG TO THE SERVICE PANEL.
WARNING – USE COPPER SUPPLY WIRES ONLY.
WARNING – FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS. DO NOT
USE TO EXHAUST AIR LADEN WITH LINT, GREASE, OR OIL.
WARNING – PRODUCT INTENDED INSTALLATION IS AN INLINE DUCT FAN WITH BOTH ENDS CONNECTED TO DUCTWORK (SEE INSTALLATION
INSTRUCTIONS SECTION). FOR ANY OTHER INSTALLATION, GUARDS MUST BE INSTALLED TO PREVENT UNINTENTIONAL CONTACT WITH
MOVING FAN BLADE UNLESS THE UNIT IS MOUNTED WITH THE LOWEST MOVING PARTS AT LEAST 2.4M (8FT) ABOVE FLOOR OR GRADE LEVEL.
WARNING – FAN IS SUITABLE FOR ONLY CONNECTION TO A DUCT SUPPLYING SINGLE-ROOM DISCHARGE (MODELS: DB100C, DB200C, DB204C,
DB205C, DB206C, DB208C, DB306E, DB308E)
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. You may phone the manufacturer during
normal business hours at 1-800-999-3267 or submit your questions from our website: www.suncourt.com.
In-Line Duct Fans
are designed to boost dry conditioned (heated or cooled) indoor airflow in ducts of forced air systems with temperatures between 40°F
TM
(4°C) and 140°F (60°C). Suncourt® accepts no responsibility for use of this product in other applications.
EXPOSURE TO AIRFLOW TEMPERATURES EXCEEDING 140°F (60°C) WILL PERMANENTLY DAMAGE THE FAN AND VOID THE WARRANTY.
ELECTRICAL SAFETY INSTRUCTIONS
WARNING – To Reduce the Risk Of Fire, Electrical Shock, or Injury to Persons, Observe the Following:
Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated
construction and accessibility.
Your In-Line Duct Fan
must be connected to a 110/120 Volt AC, 60Hz fuse or circuit breaker protected power source only in a manner approved by all
TM
applicable codes. Never connect your In-Line Duct Fan
to a variable-speed (ECM) furnace blower. For a two-speed In-Line Duct Fan
isolation relays.
The power source must be protected by a fuse or circuit breaker rated at a minimum of 15 amperes.
You may also supply power to your In-Line Duct Fan
Separately).
For In-Line Duct Fans
without power cord attached, all connections to the power supply must be made inside the electrical box provided with the unit. Use
TM
power supply conductors and wire nuts of appropriate size and type. Attach a wire nut to any unused lead in a 2-speed In-Line Duct Fan
wiring must always include a ground wire properly terminated at the fan (green wire).
For In-Line Duct Fans
with power cord attached, the cord can be plugged in to any standard (NEMA 5-15) 3-prong outlet. The outlet supplying power to the
TM
cord must include a ground terminal properly connected to a ground source. The power cord should be secured to a location where it is not subject to
damage, abrasion, or temperatures exceeding 140°F (60°C).
GENERAL INSTALLATION NOTES
For maximum performance and minimum noise, the best location to install your In-Line Duct Fan
To prevent air leaks, use a good quality aluminum foil duct tape to seal the seams in the ductwork after installing the In-Line Duct Fan
By utilizing tapered reducers, you may install larger diameter duct fans in smaller diameter ducts to achieve greater boosted airflow.
Always leave your In-Line Duct Fan
ACCESSORY INFO
Ductstat® Temperature Sensitive Switch™, model DS100
The In-Line Duct Fan
can be controlled by our Ductstat
TM
Simply plug your fan into the Ductstat
www.suncourt.com for more info on the Ductstat
Standard Variable Speed Control, model VS100
The speed of your non-corded In-Line Duct FanTM (models DB412E, DB414E, DB416E) can be controlled with our model VS100 Variable Speed Control.
This speed control utilizes solid-state circuitry to safely adjust the fan speed without damaging the motor. The speed control mounts inside a standard 2x4
electrical box and includes a cover plate and mounting hardware.
WARNING – NEVER USE A RHEOSTAT OR LIGHT DIMMER SWITCH TO CONROL YOUR FAN SPEED. A SOLID-STATE SPEED CONTROLLER
MUST BE USED TO AVOID DAMAGE TO THE MOTOR.
to a 240 Volt AC blower motor or other 240 Volt AC system. Never connect your In-Line Duct Fan
TM
using the Suncourt® DuctStat
TM
accessible for maintenance, cleaning, or repair.
TM
to operate the fan. This is the easiest way to interlock your In-Line Duct Fan
®
and set the controls to operate the fan only when conditioned air is sensed inside the boosted duct. Please visit
®
Temperature Sensitive Switch
®
, never connect directly to multiple taps on the furnace blower; always use
TM
Temperature Sensitive Switch
®
is 6–10 feet from the register that needs the boosted air.
TM
.
TM
or a standard on/off switch (Purchased
TM
. The power supply
TM
.
TM
to your furnace.
TM
TM

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Suncourt Duct Fans DB100C

  • Página 1 (heated or cooled) indoor airflow in ducts of forced air systems with temperatures between 40°F (4°C) and 140°F (60°C). Suncourt® accepts no responsibility for use of this product in other applications. EXPOSURE TO AIRFLOW TEMPERATURES EXCEEDING 140°F (60°C) WILL PERMANENTLY DAMAGE THE FAN AND VOID THE WARRANTY.
  • Página 2 Make sure you connect the colored wire as shown in the table below. Failure to connect correctly will destroy the motor. Make sure to attach a wire nut to any unused wire lead. No warranty claim for an incorrectly wired motor will be accepted by Suncourt®.
  • Página 3: Cleaning And Maintenance

    CLEANING AND MAINTENANCE Suncourt® Inc. recommends that you clean your In-Line Duct Fan™ at regular intervals, similar to what is recommended for the fan of your furnace, no less than twice a year. Keep your In-Line Duct Fan™ free of lint, dust, and debris. The In-Line Duct Fan™ must never be exposed to temperatures over 140°F (60°C).
  • Página 4: Información De Accesorios

    Enchufar el ventilador en el Ductstat® los y siga las instrucciones para operar el ventilador Cuando sólo aire caliente o frío se detecta Dentro del conducto. Por favor, visite www.suncourt.com para obtener más información sobre la Ductstat® Temperatura Switch sensible.
  • Página 5: Instrucciones De Cableado Para Duct Fans ™ En Línea Sin Cables De Corriente Adjuntos

    UN AÑO DE GARANTÍA Con sujeción a las siguientes limitaciones, la empresa fabricante, Suncourt®, garantiza que durante un (1) año a partir de la fecha original de compra minorista, pero sin exceder un plazo de dos (2) años a partir de la fecha de fabricación, el Inductor® In-Line Duct Fan™ no presentará defectos de fabricación, o de materiales.
  • Página 6: Consignes De Sécurité Électrique

    Un ventilateur de conduit sont conçus pour augmenter sèche climatise (chauffé ou refroidi) intérieur débit d'air dans les conduits forceé de systèmes à air avec des températures entre 40° F (4° C) et 140° F (60° C). Suncourt® accepte aucune responsabilité pour l'utilisation de ce produit dans d'autres applications.
  • Página 7 Norme de contrôle de vitesse variable, modèle VS100 La vitesse de votre non-filaires conduit un ventilateur de conduit (modèles DB412E, DB414E, DB416E) peuvent être contrôlés avec modèle Suncourt® VS100 Contrôle de vitesse variable. Cette régulation de vitesse utilise solid state circuits en toute sécurité pour régler la vitesse du ventilateur sans endommager le moteur.
  • Página 8: Nettoyage Et Entretien

    GARANTIE D’UN AN Sous réserve des limitations suivantes, Suncourt® (le fabricant) garantie un ventilateur de conduit contre tout défaut de pièce et de main d'oeuvre pour une période d'un (1) an à partir de la date d'achat original, mais n'excédant pas deux ans à partir de la date de fabrication. Cette garantie est sous réserve des limitations suivantes: (a) la responsabilité...

Este manual también es adecuado para:

Duct fans db200cDuct fans db204cDuct fans db205cDuct fans db206cDuct fans db208cDuct fans db210c ... Mostrar todo

Tabla de contenido