FUNCTIONING INSTRUCTIONS
The user must connect two switches (not supplied) as shown in the wiring diagram with
the following functions:
- STOP/START: It activates the strobe lights connected to the power supply, and also
lights the pilot of lamp failure.
- LOW INTENSITY: When connecting the power supply, the functioning mode is the
high intensity mode. By means of this switch, can be commuted to low intensity, switching it off
(ON position).
- LAMP FAILURE DETECTION: In case that one of the lamps fails more than two
consecutive flashes, the power supply will automatically deactivate both lamps and extinguish
the lamp failure pilot. To unlock the lamp failure system it is necessary to re-set the power
supply. Wait about 12 seconds before connecting it again.
NOTE: The use of this LOW INTENSITY function is not allowed in the lightbars
homologated according to the R65 Standard.
P8000 blue with FA-702DF (12V) with homologation number: B1 E9 001003
P8000 amber with FA-702DF (12V) with homologation number: A1 E9 001002
COMPONENTS SITUATION
FA-702DF
9
F: 15A. FUSE FOR
PROTECTION OF THE
POWER SUPPLY