ENGLISH
INSTALLATION INSTRUCTIONS
CAUTION: Before starting, turn off
power at main circuit panel.
Not suitable for use in damp or wet
locations.
Not for use with dimmers.
Turn off electrical power before modi-
fying the light system in any way.
IMPORTANT!
There must be a gap of at least 12"
(30.5 cm) between the lighting sys-
tem and an adjacent wall.
For safety reasons the wires must not
be extended.
It may be necessary to tighten the
wires some time after installation.
The lighting system is not designed
to take more than 5 spotlights. Max
100 W.
Suspend the wires for different
lighting systems so that they can not
come into contact with each other.
Do not fit any further additions to the
system (for decorative purposes, for
example).
Do not install any luminaire closer
than 6 inches (15.25 cm) from any
curtain, or similar combustible mate-
rials.
2
Do not conceal or extend bus bar con-
ductors through a building wall.
Do not install any part of this system
less than 7 feet (2.2 m) above the
floor.
To reduce the risk of fire and burns,
do not install this lighting system
where the uninsulated open bus bar
conductors can be shorted or contact
any conductive materials.
AA-67976-4