Step 5 –Attach Reflector
Assembly to the top of Head
Assembly
■ Attach reflector assembly to the
top of head assembly by sliding
over reflector stud (3pcs). Fasten
with flat washers (6pcs) and wing
nuts (3pcs). Please see Figure 11.
Connect Hose & Regulator to Cylinder
Step 1 – Gas Cylinder Required
You must provide propane gas and propane cylinder. Use a standard 20lb.
propane cylinder only.
Use this heater only with a propane vapor withdrawal supply system. See
Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum
Gas, ANSI/NFPA 58.Your local library or fire department will have this book.
Maximum supply pressure of 250 psi. A minimum supply pressure of 11.0
W.C. is required for the purpose of input adjustment for propane gas.
■ The pressure regulator and hose assembly supplied with the appliance must be used.
■ The installation must conform with local codes, or in the absence of local codes, with
National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Natural & Propane installation code,
CSA B149.1 as applicable.
■ A dented, rusted or damaged propane cylinder may be hazardous and should be
checked by your cylinder supplier. Never use a propane cylinder with a damaged valve
connection.
■ The propane cylinder must be constructed and marked in accordance with the
specifications for LP gas cylinders of the U.S. Department of transportation (DOT) or
the Standard for Cylinders Spheres &Tubes for transportation of Dangerous Goods &
Commission, CAN/CSA-B339, as applicable.
■ Never connect an unregulated propane cylinder to the heater.
■ Provided with a listed overfilling prevention device.
■ Provided with a cylinder connection device compatible with the connection for the
appliance.
■ Do not store a share LP-Gas cylinder under or near this appliance.
■ Place the dust cap on the cylinder valve outlet when ever the cylinder is not in use.
Only install the type of dust cap on the cylinder valve is provided with the cylinder
valve.
Figure 11
Figure 12
20LB Propane Cylinder