NOTE: The stored temperature is continuously visualized till START is pressed, after that the
discharge temperature appears.
3.2 OPERATION WITH 80 PROGRAMS
3.2.1 Initial recipes setting
Set the program No. (ex. P01 then P02 etc.) appearing on the lower display (9) (PROGR. lights
up) and then the desired water quantity, appearing on the upper display (16).
To store the temperature, press the
It is possible to exit from a recipe setting dosing the recipe itself (press START), setting a new
recipe (press P...), or automatically after 10 seconds: in all these cases the recipe is stored.
Warning
: recipe numbers from 1 to 9 must be always set using the format: 01, 02, etc..
3.2.2 With recipes already programmed:
To recall a recipe, enter the desired No. (for example P28), which is shown for 3" on the lower
display (9), while the upper displays show the relevant quantity and temperature.
Press START to carry out the dosing. If modifications are required, set the new quantity and/or
temperature as explained above.
To stop water delivery manually at any time press the STOP/C key. After that on the display (16)
the delivered water quantity flashes; to resume dosing press again the START key, otherwise,
pressing the STOP/C key, the quantity is cleared and it is possible to set a new quantity. To
modify the temperature, press
3.3 USE OF EXTERNAL PROBE
The equipment is fitted with an auxiliary precision electronic thermometer with a mobile probe
(6), usable at distances up to 5 metres.
Temperature readout on the display (9) is continuous, except if the program No. appears.
3.4 SPECIAL FUNCTIONS
With the double pression of the P key, the device shows the succession of the recipes stored
in memory.
Holding the
decimal number) is indicated: see example in Figure 9.
DOMIX 45 A – 2600111 – 11.09.2001
key and proceed as for manual operation.
and proceed as already described.
key for 10", the total amount of the m
2
t
M
3
4
5. 7
o
t
E
M
Figure -9
delivered by the machine (with a
4