ART 7/G2+ MONITOR
SAFETY PRECAUTIONS
Always disconnect the power supply
-
before installing or making modifications to the device.
.
- The fitting and handling of these devices must be carried out by
.
- The wiring must run at least 40 cm. away from any other wiring.
- Do not overtighten the screws on the connector.
- Install the monitor in a dry protected location free from the risk of dripping or splashing water.
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Before connecting the device to the mains, check the connections between the door panel, power
supply, distributors and monitors.
-
Always follow the instructions contained in this manual.
CHARACTERISTICS
( )
*
-
Hands-free monitor.
-
7" TFT c
olo r
u screen
.
-
Hidden push button
for access and selection of menu function.
- Monitor
with simple installation (non-polarised 2 wires bus)
-
User menu
.
-
Installer menu
.
-
Image and communication settings menu
.
-
Output auxiliary call repeater (max.
50mA/12V ).
-
"HZ" input for calls from apartment front door
button "HZ" activated at the same time (with system and monitors in standby).
- Hidden push buttons for Door release 1 and 2.
-
Notification l
eds.
-
Configuration switches to assign the address and to define whether the monitor is master or slave
SYSTEM OPERATION
( )
*
-
To make a call, the visitor must press the button of the apartment; an audible sound indicates that the
call is being made and
the door panel
LED
progress' message appears indicating that a call is being made. At this moment, the apartment's
monitors receive the call. If another apartment is called by mistake, press the button for the correct
apartment and the first call will be cancelled.
- Upon receiving the call, the image will appear on the screen of the master monitor (and slave 1, if it exists)
without the visitor knowing and icon
displayed on the screen will blink green. To view the image from
slave monitors 2 or 3, press the one of the hidden buttons (located above the raised dots for the visually
impaired) of the monitor to display
the image. If the call is not answered within 45 seconds,
panel
LED
will turn off and the system will become free.
- To establish communication, press
the hidden push button below
screen. Door panel LED
will turn off and the led
-
Connection will last for 90 seconds or until
the hidden push button below
the
on the screen
is pressed
. When communication ends,
will become free. If vocal synthesis is enabled, a 'Communication is finished' message will indicate that
the call is over.
-
To open door
or
of the door panel press the
,
1
2
displayed on the screen
during the call or communication processes: one press will activate the lock
release for
3
seconds and
the door panel
LED
enabled, a 'Door open' message will be indicated on the door panel.
is
- Detailed operation
and configuration
of the monitor
INSTALA
TION OF THE
MONITOR
( )
*
( )
( ) For more information, see
"TART 7/G2+
user manual
*
https://doc.golmar.es/search/manual/50122464
authorised personnel
.
.
dc
Important:
.
Up to 8 monitors/ apartments with push
.
will turn on. If vocal synthesis is enabled, a 'Call is in
the door
off-the-hook icon
shown
will
turn on
.
on-the-hook icon
shown on
door panel
LED
will turn off and the system
hidden push button below of
corresponding icon
will also turn on for
3
seconds. If vocal synthesis is
, see "TART /G2+"
7
monitor
user manual
.
(cód. 50122464)".
2
ART 7/G2+ MONITOR
DESCRIP
TION
MONITOR
( )
*
A
B
C
*
Hidden button
pressing area
D
H
I
J
H
( )
Monitor address (code) setup:
*
Dip1 Dip5:
-
Sets the monitor address (addresses to 3 ).
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
monitor code is the sum of the values of the switches set to ON.
Important: Apartment 1 (Dip1 to ON & Dip2-Dip5 to OFF).
Important: Apartment 32 (Dip1 - Dip5 to OFF).
Dip6-Dip7: These define whether the monitor is master or slave. Each apartment must have one master monitor, and only
one. In the case of apartments with more than one monitor, the monitor with Wi-Fi transmitter should always be the master.
Master
ON
1
2
3
4
5
6
7
8
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable
ends. Deactivate it only in intermediate monitors.
on the
Dip1 to Dip5: These assign the address of the corresponding monitor to its call button on the door
panel. Switches 4-5 must remain in the OFF position.
Apartment 1
ON
1
2
3
4
5
6
7
8
Dip6-Dip7: These define whether the monitor is master or slave. Each apartment must have one master monitor,
and only one.
Master
ON
1
2
3
4
5
6
7
8
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable ends.
Deactivate it only in intermediate monitors.
( )
For more information, see
*
https://doc.golmar.es/search/manual/50122464
EN
A. Speaker.
B. Notifications icons:
Power on indicator.
Do not disturb.
Auxiliary relay activated.
Door opening.
New image/video.
E
C. Hidden push button indicator Leds
To access the main menu (monitor in standby),
of the 2 hidden buttons with indicator LEDs illuminated,
located above the raised dots for the visually impaired see
"TART 7/G2+" manual
In call/ communication an LED shows the location of each of
G
the hidden buttons.
F
<the function of each hidden button is shown on the monitor
screen with an icon located just above each button see
"TART 7/G2+" manual
D. Raised dots for the visually impaired.
In standby:
Above the raised dots for the visually impaired
the
hidden buttons that access the main menu.
12210701
Product Version:
V0
3
MONITOR 7" ART 7/G2+
H
In call:
GOLMAR S.A.
CAUTION
C/ Silici, 13
08940 - SPAIN
TO PREVENT ELECTRIC SHOCK,
WARNING
DO NOT REMOVE COVER. NO
TO PREVENT FIRE OR ELECTRIC
USER SERVICEABLE PARTS
SHOCK, DO NOT EXPOSE THIS
INSIDE. REFER SERVICING TO
Above this raised dot is the hidden
DEVICE TO RAIN OR MOISTURE
QUALIFIED SERVICE PERSONNEL.
ON
com unica
m
1
2
3
4
5
6
7
8
Above this raised dot is the hidden Door opening button
SA
J
GND
E.
7"
TFT colour screen.
HZ
HZ
F.
Micr
ophone
.
DIP 1 to 5
DIP 6,7
SA
BUS
G. Micro SD card slot (not included).
Monitor address
00 - Master
GND
10 - Slave 1
IN
DIP 8
HZ
01 - Slave 2
BUS
H
End of line resistor
11 - Slave 3
HZ
OUT
OFF = 0 | ON = 1
T p : MicroSD Clas 10
y e
H. Wall mounting connector fixing (x4).
I.
Configuration switches.
J.
Installation terminals.
Building / Villa (Nexa Door Panel)
1
2
Table of values
Switch number:
1
2
3
Value when ON
:1
2
4
Slave 1
Slave 2
ON
ON
1
2
3
4
5
6
7
8
1
2
3
4
5
6
Villa (Soul Door Panel)
*
Apartment 2
Apartment 3
ON
ON
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Slave 1
Slave 2
ON
ON
1
2
3
4
5
6
7
8
1
2
3
4
5
6
"TART 7/G2+
user manual
(cód. 50122464)".
3
*
:
pres
s either
(
).
:
(
).
/
are
"
Start End
/
tion button
"
.
"
"
.
s
from
4Gb
to
128Gb.
ON
4
5
1
2
3
4
5
6
7
8
8 16
Example: 0+ 0+4+0+16 = 20
Slave 3
ON
7
8
1
2
3
4
5
6
7
8
*
Apartment 4
ON
Kit Soul / Art 7
1
2
3
4
5
6
7
8
manual
Slave 3
ON
7
8
1
2
3
4
5
6
7
8
EN

Publicidad

loading

Este manual también es adecuado para:

50122464