Technical Specifications; Troubleshooting - Balcrank 3120-114 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Type
Wetted part materials
Inlet connection
Outlet connection
Maximum working pressure
Compatible fluids
Flow
Viscosity range
Operating temperature
Precision
Pulse ratio
Pushbutton actuation force
Weight
Dimensions
Symptom
The meter is inaccurate.
Reduced flow.
The meter does not count.
4
SB 3099 R. 07/17
Balcrank
Corporation · Weaverville, NC 28787 · 800-747-5300 · 800-763 0840 Fax · www.balcrank.com
®

Technical Specifications

Oval gear meter.
Aluminium, Acetal, NBR, Stainless Steel.
1/2" NPT and flange.
1/2" NPT and flange with seating for O-ring.
1,500 psi (100 bar).
Oil, glycol and coolant solutions.
0.25 - 8 gpm
(depending on the viscosity of the fluid and temperature).
8 a 2000 cSt.
14 ºF - 140 ºF.
±0.5%.
1241 PPG / 328 PPL / 310 PPQ
MAX 30 VDC
1.2 lb (535 gr)
3.6 in
Trouble-shooting
Possible cause
Erroneous calibration factor.
A fluid with very high or very low
viscosity is being used.
Very high or low fluid temperature.
The meter is working outside its
field of application (see technical
specifications).
Dirt in the measuring chamber.
Faulty reed sensor.
Loose connections.
Worn or damaged gears.
2.6 in
Solution
Calibrate the meter.
Calibrate the meter.
Calibrate the meter.
Restore the working conditions
(flow, viscosity, temperature...) to
those required by the meter.
Clean the measuring chamber.
Inform technical support.
Check connections.
Disassemble the meter and clean
or replace gears.