System Setup (continued)
13
Startup
Note: During Startup, you will use the Extra Cycle button to
manually advance through the stages of the regeneration cycle.
• Place the by-pass valve in the online position (handles
parallel with inlet/outlet of softener).
• Start a regeneration by holding the Extra Cycle button for
five seconds.
• Advance the system to the Backwash stage by pressing the
Extra Cycle button. Ensure that water flow from the drain line
remains steady for 10 minutes or until the water runs clear.
• Advance the system to the Brine / Slow Rinse position. Ensure
the system is drawing water from the brine tank. If not, repeat
this step three times to purge air from the system.
• Advance the system to the Rapid Rinse position. Verify that
there is water flowing through the drain line and run for five
minutes or until the water runs clear.
• Advance the system to the start of the Brine Tank Fill cycle.
Ensure water fills the brine tank at the desired rate and to the
desired level (slightly over grid plate).
Note: The integrated brine valve in the brine tank will
automatically stop water fill at the correct level.
14
Add Salt
Setup is complete.
19