English
Application
Bus video line rectifier for Siedle
In-Home bus: video in switch panel
housing for power supply to the
bus users.
Application
The line rectifier may only be used
exclusively to supply Siedle appli-
ances. Any other application is
deemed not in accordance with its
intended use and exonerates the
manufacturer from any liability.
Electrical voltage
• Mounting, installation and ser-
vicing work on electrical devices may
only be performed by a suitably
qualified electrician. Failure to
observe this regulation could result
in the risk of serious damage to
health or fatal injury due to electric
shocks.
• Operation at an altitude of up to
2000 m above sea level.
• Observe EN 62368-1!
In a building installation, an all-
pole mains switch with a contact
opening of at least 3 mm must be
provided. The device must not be
exposed to water drops or sprayed
water! Sufficient ventilation must be
ensured. Pay particular attention to
ensure that ventilation slots are not
covered.
• When using stranded cores as
cable material, these must be fitted
with wire end ferrules without fail.
Scope of supply
• Line rectifier for top hat rail
mounting
• Siedle In-Home bus system manual
• This product information
Accessories
ZBVG 650-...: Is required in sys-
tems with more than one line or
for programming the in-home bus
via a Windows PC (BPS 650-...)
and PRI 602-... USB. Only one unit
may be installed within the Siedle
In-Home bus.
Mounting
1 Clip the bus line rectifier onto the
top hat rail.
Terminal assignment
L1, N
Power connection
TaM, TbM In-Home bus monitor
branch
TaK, TbK
In-Home bus camera
branch
Sa, Sb
System bus audio
SaV, SbV
System bus video
Tö, Tö
Relay contact door
release
Li, Li
Relay contact light
Installation and commissioning
Installation, commissioning and pro-
gramming are described in the Siedle
In-Home bus system manual.
Specifications BVNG 650-0
Operating voltage: 230 V AC,
+/-10 %, 50/60 Hz
Operating current: 300 mA
Output voltage:
29 V DC stabilized +/-5 %
Output current: 1.2 A
Fusing: primary thermal fuse,
secondary short circuit proof
Contact type: 2 n.o. contacts 24 V,
2 A
Protection system: IP 30
Ambient temperature:
0 °C to +40 °C
Horizontal pitch (HP): 9
Dimensions (mm) W x H x D:
162 x 89 x 60
Specifications BVNG 650-1
Operating voltage:
120 V AC +6 %/-10 %, 50/60 Hz
Operating current: 560 mA
For further technical specifications
see above
3