User Manual
EN
FireWare Vesta
Component
Gas cylinder
Gas cylinder (propane,
butane)
Connectors
Gas cylinder
Gas hose
Pressure regulator
Flame extinguisher
Take note: make sure the charger is set to 12 Volt.
Connect the charger to the FireWare Vesta. Always do this in a well-ventilated area. When
the green light on the charger is on, the battery is charging. As soon as the battery is full
(this takes about 6 hours), the green lamp goes off and the charger no longer generates
a charge. If the red lamp is on, the battery is not charging. In that case, please
contact FireWare.
ALWAYS check the gas hose and the power cable before you use the FireWare Vesta.
2.
Before using the FireWare Vesta, make sure it is fully charged.
3.
Place the FireWare Vesta in a safe location and connect the remote control. The plug fits on
the connection of the fire extinguisher trainer in only one way. Then switch the plug on.
4.
Place the gas cylinder in a safe location at a distance of at least 5 meters from the fire
extinguisher trainer. Connect the hose to the FireWare Vesta first, it is a click system. Then
connect the other end with the twist-on connector to the gas cylinder.
There is a pressure regulator valve mounted between the gas cylinder and the gas hose.
This regulator valve has a range of up to 4 bars and is suitable for an output of 12 kg/hour.
Take note: First turn the regulator valve completely back to 0 bars (clockwise) before you
open the gas tap. Open the gas cylinder slowly. If you hear a hissing sound, close the tap
and check the connections once again. If you cannot find the cause, contact FireWare.
5.
Open the gas cylinder completely and open the regulator valve to 1 bar. Check the
connectors again for gas leaks using leak-check spray. By turning the regulator valve
(counter clockwise), you can adjust the flame height. Low pressure (0.5 to 1 bar)
gives a small flame and if you open the regulator valve completely (4 bars) you will achieve
the biggest flame.
Take note: With ignition, open the regulator valve to maximum 2 bars. Once the FireWare
Vesta is burning, you can open the regulator valve further to 4 bars. If the pressure is set to
high, you can reduce it during ignition. This could happen for instance when you do multiple
exercises shortly after one another.
www.FireWare.nl
Activity
Inspecteren op beschadiging
Check rubber in connection
Check for gas leaks using
leak-check spray
Check inspection date, if
necessary, have it re-checked
Date of inspection, replace if
necessary
Date of inspection, replace if
necessary (2 years)
Date of inspection, replace if
necessary (2 years)
Before USE
Every 3 months
X
X
X
X
X
X
X
FireWare Vesta
Afbeelding 2
21