4-CONDUCTOR POWER CORD INSTALLATION
Use this method for new installations and whenever 4-conductor installation is required.
•
Remove the wire cover (on the back of range) by removing 3 screws using a Phillips screwdriver. The terminal block will
then be accessible.
•
Remove the knockout ring (1 3/8") located on bracket directly below the terminal block. To remove the knockout, use a
pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed.
•
Assemble a U.L.-listed strain relief in the opening.
•
Insert the power supply cord through the strain relief, allowing enough slack to easily attach the wiring to the terminal
block.
•
Use only ring terminals to connect the power supply.
•
Remove the ground-link screw from the range frame. Save the ground-link screw. Bend the ground link away from the
range so that it does not contact the range.
•
Connect the green ground wire from power supply cord to the range using the ground-link screw. The ground wire must
be attached first and must not contact any other terminal.
•
Use a ¼" nut driver and remove the hex washer head nuts from the terminal block.
•
Connect the outer wires to the outside terminals and the center wire to the center terminal. Securely tighten nuts for
proper electrical connection.
•
Tighten the strain relief screws.
•
Re-install the wire cover with the 3 screws removed earlier. Make sure the wires do not become pinched between the wire
cover and main back.
FACTORY INSTALLED CONNECTIONS
(DO NOT LOOSEN)
CONNECT LINE 1
HERE
CONNECT NEUTRAL
HERE
BLACK WIRE
GROUND STRAP
FACTORY INSTALLED CONNECTIONS
(DO NOT LOOSEN)
CONNECT LINE 1
HERE
CONNECT NEUTRAL
HERE
BLACK WIRE
GROUND STRAP
TERMINAL BLOCK
CONNECT LINE 2
HERE
RED WIRE
(NEUTRAL)
WHITE WIRE
TERMINAL BLOCK
CONNECT LINE 2
HERE
RED WIRE
(NEUTRAL)
WHITE WIRE
GREEN
GROUND WIRE