Removal From Window - Kenmore 580.74055 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

r_
INSTALL THE AIR CONDITIONER IN THE
WINDOW
• Carefully lift the air conditioner
and slide it into the open
window. Make sure the bottom guide of the air
conditioner drops into the notches of the L brackets.
• When the air conditioner drops into the L brackets, the
air conditioner will be centered in window opening as
shown in FIG. 7.
• While steadying the air conditioner,
carefully bring the
window sash down behind the upper guide of the air
conditioner,
as shown in FIG. 8.
\
I
CENTER LINE
FIG. 7
FIG. 8
W
SECURE THE GUIDE PANELS
Extend the guide panels (ITEM G) to fill the window
opening using 2 ITEM B and 2 ITEM C screws to secure
them, as shown in FIG. 9.
l_
INSTALL
THE FOAM SEAL AND SASH LOCK
• Cut the foam seaI (ITEM F) to the window width.
Stuff the foam seal between the lower and upper
window sash to prevent air and insects from getting into
the room, as shown in FIG. 9.
• Fasten the remaining L bracket on either side of the
window using screw (ITEM A). See FIG. 9 inset.
Installing this bracket prevents unit falling from window
being raised.
LBRACKET
ITEM C
FOAM SEAL
(ITEM F)
FIG. 9
Q
IF AIR CONDITIONER
IS BLOCKED
BY STORM
WINDOW FRAME
• If storm window presents interference,
fasten a 2" wide
wood strip to the inner window sill across the full width of
the sill. The wood strip should be thick enough to raise
the height of the window sill so that the unit can be
installed without interference from the the storm window
frame. See FIG. 10.
Top of wood strip should be approximately
3/4" higher
than the storm window frame to help condensation
to
drain properly to the outside.
• Install a second wood strip (approximately
6" long by
11/2" wide and same thickness as first strip) in the center
of the outer sill flush against the back of the inner sill.
Screw the L brackets into this strip.
This will raise the L bracket as shown in FIG. 10.
WOOD STRIP MOUNTED
1" MAX
3/4"
ON TOP OF INNER SILL
CLEARANCE ±Y
INNER
SILL
INSIDE
WINDOW
FRAME
WOOD STRIP
_
FOR L BRACKET
OIJTER
SILL
TSIDE FIG. 10
REMOVAL FROM WINDOW
Turn the air conditioner
off, and disconnect
the power
cord. Remove the L bracket and the screws installed
through the top and bottom of the guide panels, and save
for reinstallation
later. Close the guide panels. Keeping a
firm grip on the air conditioner,
raise the sash, and
carefully tilt the air conditioner
away from you to drain any
condensate water. Lift the air conditioner from the window
and remove the foam seal from between the windows.
• Air conditionerscoveredin this manualposean
excessiveweight hazard.Two or morepeopleare
neededto moveand installthe unit.
To preventinjuryor strain,useproperliftingand
carryingtechniqueswhenmovingunit.
• Whenhandlingthe air conditioner,be carefulto avoid
cutsfrom sharpmetalfins on front and rear coils.
• Make sureair conditioner does notfall duringremoval.
-7-

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido