P13: Equipment communication address, range from 1-255. (System default is 001)
P14: Equipment types
• 000: swing barrier =001: wing barrier(Flap barrier)
P15: System default reset , when P15 appear, press SET Key, it will display P-2, press
INC to reset system default.
P16: Normal open ,Normal close ,Normal mode , (System default is 000)
• 000: Normal close
• 001: Normal open
P17: Sensor delay function(customized function ,system default000)
•001: The gate delay 1s to close after people pass turnstile (maximam10s)
P18: Sensor anti-clamp delay function(customized function ,system default 000)
• 001: The gate delay 1s to close after people pass middle anti-pinch sensor (maxi-
mam10s)
P19: Motor setting (system default 000)
3. Back from menu setup
Press INC Key or DEC Key, when it display the word POO, press SET Key to back
from menu setup.
Electric Swing Barrier
Communication Protocol
1.
Hardware Protocol
• Communication signal: RS485,
• Communication baud rate: 9600bps Start and end from one bit
• Data bits: 8 bits
• Parity check bit: No
2.
Frame Rate Agreement
1. The frame format of upper computer: Synchronization code + equipment ad-
dress + command code + check code
Synchronization code: Receiving and sending message in hex 235 ( decimal sy-
stem)
Equipment address: Sending and receiving message in hex Equipment address
10