General Information/ Informações Gerais/
Informaciones Generales
• The optical terminal closure FK-CTO-16MT is a product of external use for
installation in aerial networks (pole or wall).
• It has mechanical sealing in the main input and branching ports, which is
compatible with cable diameters from 6 mm to 12 mm, with the use of
grommets (6-9 mm and 9-12 mm).
• It has 2 entrance ports with mid spain possibility and 2 derivation ports.
• It has access for up to 16 drop cables.
• It supports up to 26 optical fusion and installation for up to 2 splitters.
• A caixa de terminação óptica FK-CTO-16MT é um produto de uso externo
para instalação em redes aéreas (poste ou parede).
• Tem fechamento mecânico nas portas de entrada principal e de derivação,
compatível com diâmetros de cabos de 6 mm a 12 mm, com uso de
grommets (6-9 mm e 9-12 mm).
• Tem 2 portas de entrada com possibilidade de sangria e 2 portas de
derivação.
• Acesso para até 16 cabos drops.
• Suporta até 26 emendas ópticas e instalação de até 2 splitters em uma
única bandeja.
• La caja de terminación óptica FK-CTO-16MT es un producto de uso
externo para instalación en redes aéreas (poste o pared).
• Tiene sello mecánico en los puertos de entrada principal y derivación,
compatible con diámetros de cables de 6 mm a 12 mm, con uso de
grommets (6-9 mm y 9-12 mm).
• Tiene 2 puertos de entrada con posibilidad de sangrado y 2 puertos de
derivación.
• Acceso para hasta 16 cables drops.
• Soporta hasta 26 empalmes y instalación de hasta 2 splitters en una
bandeja.
Care and Safety/ Cuidados e Segurança/
Cuidado y Seguridad
• Proper precautions must be taken when handling optical cables and
optical cords, especially in bare optical fiber handling.
• During accommodation of the basic units within the product, check the
bending radius and interference with other components while opening
and closing the box.
• Optical connectors must be cleaned before each connection and every
reconnection.
Stay alert for laser radiation warnings, do not manipulate connectors
when lasers are on and do not turn the connectors towards the eyes.