TEST AND ADJUSTMENT
1. Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
before it will detect motion. When first turned
on, wait 1
/
minutes.
1
2
2. Turn the SENSITIVITY (SENS) control to theminimum
position (MIN) and the ON-TIME control to the TEST
position.
ON - TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
Maximum Range
/
minute warm up period
1
2
SENS
MIN
MAX
60 ft.
(18.3 m)
Maximum
Coverage Angle
NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
Motion
Least Sensitive
3. Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
4. Walk through the coverage
area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cover-
age area.Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
5. Adjust the SENSITIVITY
a s n e e d e d . To o m u c h
sensitivity may increase false
triggering.
6. Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
7. Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
WARNING: Risk of fire. Do not aim the bulbs
at a combustible surface within 3 ft. (1 m).
110°
4
Motion
Sensor
Most Sensitive
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
598-1159-07