Owner's Instructions:
The Garage Door Opener Surge Protector is designed to protect LiftMaster
damage from lightning and power surges. The Surge Protector will stop radiated surge currents from
coming through wall control and safety sensors, as well as surge currents from coming through AC power
line according to the rating chart shown below.
Plug the Surge Protector into grounded (3-wire) 120V AC outlet within four (4) feet of the garage door
opener. Plugging Surge Protector into a GFCI (Ground Fault Circuit Interrupter) is acceptable, but not
recommended as power surges may cause the GFCI to trip and you will need to reset the outlet in order
to operate the garage door opener.
To prevent possible SERIOUS INJURY or DEATH from electrocution:
• Unplug garage door opener from AC outlet and be sure power is disconnected BEFORE
installing the Surge Protector.
• Connect terminals ONLY to 24 VOLT low voltage wires.
• The Surge Protector is ONLY for indoor Use.
• DO NOT perform installation during a lightning storm (visible lightning)
Installing the wall control wires:
• At the garage door opener, remove the white-white/red wires (for wall control) from Quick-Connect terminals.
• Using a 5' piece of white-white/red 22 AWG bell wire (not included), strip 7/16" of insulation from both ends.
• With existing wall control wire and new wire, use pliers to twist same colored wires together.
• Referring to wiring diagram, insert wall control wires into red and white connectors on Surge Protector.
• Insert opposite ends of new wire into Quick-Connect terminals located on garage door opener as follows:
white to white and white/red to red.
Installing the safety sensor wires:
• At the garage door opener, remove the white-white/black wires (for safety sensors) from Quick-Connect terminals.
• Using a 5' piece of white-white/black 22 AWG bell wire (not included), strip 7/16" of insulation from both ends.
• With existing safety sensor wires and new wire, use pliers to twist same colored wires together.
• Referring to wiring diagram, insert safety sensor wires into white and gray connectors on Surge Protector.
• Insert opposite ends of new wire into Quick-Connect terminals located on garage door opener as follows:
white to white and white/black to gray.
Installing the Surge Protector:
• Plug Surge Protector into AC outlet
• Plug garage door opener into outlet on front of Surge Protector
• Test garage door opener for proper operation. Be sure to test all functions including wall control, keypad, safety
sensors (Door Reversal Test - See garage door opener manual for instructions) and any other accessories.
LED Indicator: The indicator light should be illuminated when the surge protector is plugged into AC power and is
protecting your garage door opener system. If the indicator light goes out, the surge protector has sacrificed
(depleted) itself to protect the garage door opener system and should be replaced immediately.
RATING CHART / TECHNICAL SPECIFICATIONS
Energy Dissipation: 761 joules
Line Voltage: 120 VAC, 50/60Hz
Protection Indicator Light: Yes
Maximum Surge Current: 16kA
Catastrophic Surge Circuit: Yes
Maximum Surge Voltage: 6kV
Thermal Fusing: Yes
Line Current: 15 Amp
© 2005, All Rights Reserved The Chamberlain Group, Inc.
Model 990LM
Garage Door Opener
Surge Protector
garage door openers against
®
WARNING
Power: 1800 Watts
UL1449 Suppression Rating: 800V
Protection Modes: L-N, N-G, L-G
3
3
2
2
7/16"
Strip wire both ends
of the wires 7/16"
White/Black Wire
Garage Door
SAFETY SENSORS
FOR TECHNICAL SUPPORT, DIAL OUR TOLL FREE NUMBER: (USA) 1-800-528-2817
Chamberlain Connected Equipment Limited Warranty
Chamberlain warrants to the original purchaser of any Chamberlain Surge Protector that the surge protector shall be free of defects in
material and workmanship for a period of five (5) years from the date of original purchase, and will repair or replace, at its option, any
defective surge protector free of charge. The proper operation of the Chamberlain Surge Protector may destroy the protector itself.
Such an event is not a defect and is not covered by this limited warranty.
For a period of five (5) years from the date of original purchase of any Chamberlain Surge Protector, Chamberlain will repair or
replace, at its option, any LiftMaster garage door opener ("Connected Equipment") which is damaged by a transient voltage surge (an
"Occurrence"), while properly connected through a Chamberlain Surge Protector to a properly wired AC power line with protective
ground. This limited warranty is null and void unless all wires leading into the equipment pass through an appropriate Chamberlain
Surge Protector as further described herein. Chamberlain reserves the right to review the damaged Chamberlain Surge Protector, the
damaged Connected Equipment and the site where the damaged occurred. All costs of shipping the Chamberlain Surge Protector
and the damaged equipment to Chamberlain for inspection shall be borne solely by the purchaser. Damaged equipment must remain
available for inspection until the claim is finalized.
All above warranties are null and void if the Chamberlain Surge Protector in use during the occurrence is not provided to Chamberlain
for inspection upon Chamberlain's request at the sole expense of the purchaser, Chamberlain determines that the Chamberlain Surge
Protector has been improperly installed, altered in any way or tampered with, Chamberlain determines that the damage did not result
from the occurrence or that no occurrence in fact took place, or Chamberlain determines that the Connected Equipment was not used
under normal operating conditions or in accordance with all labels and instructions. All Chamberlain Surge Protectors must be
plugged directly into the power source and must not be "daisychained" together in serial fashion with other power strips, UPS, other
surge protectors or extension cords. Any such installation voids the limited warranty. This limited warranty only protects against dam-
age to properly connected equipment where Chamberlain has determined, in its sole discretion, that the damage resulted from an
Occurrence, and does not protect against acts of God such as flood, earthquake, direct lightning strike, war, vandalism, theft, normal-
use wear and tear, erosion, depletion, obsolescence, abuse, damage due to low voltage disturbances (i. e. brownouts or sags), non-
authorized program or system equipment modification or alteration. This warranty is secondary to any existing coverage of any
Connected Equipment, including, but not limited to, any manufacturer's warranty, extended warranties or insurance
coverage.
THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE, AND OF ANY OTHER
OBLIGATIONS OR LIABILITY ON SELLER'S PART. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE,
DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MIS-
USE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTER-
ATIONS TO THIS PRODUCT), REPLACEMENT OF BATTERIES AND LIGHT BULBS OR UNITS INSTALLED FOR NON-RESI-
DENTIAL USE.
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES
ARISING IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER'S LIABILITY
FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE
PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION
WITH THE SALE OF THIS PRODUCT.
Valid only in the USA and Canada.
White/Red Wire
White Wire
White Wire
White
Red
Garage Door Opener
To release wire,
Gray
push in tab with
screwdriver tip.
114A2914 Rev C
Wall
Control
LOCK
LIGHT
9
1
9
1
7
5
3
7
5
3
KG
KG
Printed in China

Publicidad

loading

Resumen de contenidos para Chamber LiftMaster Professional 990LM

  • Página 1 Model 990LM Garage Door Opener Surge Protector Wall Owner's Instructions: 7/16" Control The Garage Door Opener Surge Protector is designed to protect LiftMaster garage door openers against ® Strip wire both ends damage from lightning and power surges. The Surge Protector will stop radiated surge currents from of the wires 7/16"...
  • Página 2 Protecteur de surcharge pour ouvre-porte de garage Modèle 990LM La commande 7/16" Instructions d’utilisation : morale Le limiteur de surtension pour ouvre-porte de garage est conçu pour protéger les ouvre-portes de garage Dénuder sur 7/16 de po (1 cm) LiftMaster contre la foudre et les surtensions d’alimentation électrique. Il empêche les courants de surcharge les deux extrémités de les fils Fil blanc et noir Fil blanc et rouge...
  • Página 3 Protector de sobrecarga para abre-puertas de garaje Modelo 990LM 11mm Panel de (7/16 de pulg.) Instrucciones de uso: control El protector de sobrecarga para abre-puertas de garaje Liftmaster ® es un dispositivo destinado a la protección del sistema eléctrico contra descargas atmosf'éricas y sobretensión. Este protector suministra protección contra Pele 11 mm (7/16 de pulg.) Cable blanco/negro Cable rojo/blanco...