Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
3. Operation
3.1 Setting up the coils for a transverse field
Insert the coils into the middle of the coil slot
and push them out as far as they go. Make sure
the connectors point outwards.
Insert the hot cathode tube into the holder.
For Helmholtz configuration d = r the outer
edges of the coil base should be flush with the
dashed lines (refer to Fig. 1).
3.2 Setting up a coil for an axial field
Insert the hot cathode tube into the holder.
Slot the base of the coil into the groove from
the front making sure that the connectors point
forwards (refer to Fig. 2).
When using both coils, put the base of the sec-
ond coil onto the plugs of the first coil.
Fig. 1 Setting up the coils for a transverse field
Fig. 2 Setting up a coil for an axial field
2
3.3 Determining the current in the coils
3.3.1 Series connection
When the coils are to be connected in series,
connect terminal Z of coil 1 to terminal Z of coil
2 (refer to Fig. 3.1).
Take into account the total current when calcu-
lating B.

3.3.2 Parallel connection

When the coils are to be connected in parallel,
connect terminal A of coil 1 to terminal Z of coil
2 and terminal Z of coil 1 to terminal A of coil 2
(refer to Fig.3.2).
To calculate B the total current 2 I should be
halved since both coils have the same resistance
and half the current I passes through each one.

Publicidad