Part number: 9835663180
2. Install wall dock
Option 2:
230 V 1-phase with neutral
For 1-phase use of a Wye-connected secondary, only
a single phase (L1) and neutral must be connected.
This phase voltage must measure 230 V between line
and neutral.
Warning: In this configuration, the wall box operates
only from a single phase (L1). Do not connect the
remaining phases L2 and L3.
Option 3:
230 V 1-phase without neutral
In this configuration (without a neutral and 230 V
from line to line), connect any two lines (L1, L2 or L3)
to the L1 and neutral positions on the terminal block
of the wall box.
INSTALLATION_WALL_BOX_PSA_B2C_MERGED.indd 13
230 V
230 V
230 V
EN
L1
L2
L3
N
G
L1
L2
L3
N
G
13
11-9-2019 8:30:58