SIZING IN GALLONS
Pre-Programming Requirements
C. Calculate Metering Pump Output Requirement in Gallons per Day.
Maximum System Flow Rate (gpm) x Dosage (ppm) x 1440
Solution Strength % x 10,000 = Solution Strength ppm
*
D. Reference the chart below to confirm the selected pump's maximum output slightly
exceeds the pump output requirement calculated in C.
Stenner Fixed Output Pumps (26-100 psi)
Model
45MPHP2
45MPHP10
45MPHP22
85MPHP5
85MPHP17
85MPHP40
USA and Canada 800.683.2378, International 904.641.1666
Solution Strength ppm
Pump Tube
#1
#2
#7
#1
#2
#7
continued
*
Maximum Output (gpd)
3
10
22
5
17
40
Metering Pump
=
Output Requirement
(gpd)
9