5. INSTALLATION
UPG is supplied with the uninstalled Grip 14. Therefore, before using the device, it is necessary
to screw the Grip 14 into Eccentric 13.
6. CALIBRATION
Check leaktightness and adjust pressure in the system:
•
Put the Inserts in the Chamber
•
Close the Lid 10 with the Eccentric Lock
DANGER!
If the lid is not fixed it can be suddenly opened and injured the user.
•
Adjust the manometer with the Screws 9 if needed: loosen the Screw 16 and tighten
the Screw 9 if you need to increase pressure, loosen it to decrease pressure.
Fix the Screw 9 with the Adjusting Screw 16.
CAUTION!
Perform adjustment of pressure only when the Lid 10 is open.
•
The Manometer should indicate pressure (5±0,2) kPa ((50±2) mbar)
UPG is leaktight if the manometer is stable for 2 minutes after exposure 10-15 seconds.
NOTE!
Check leaktight of the UPG every time before its use.
7. MEASURING
For leaktight tests of the self-contained self-rescuers mechanical timer should be used together
with UPG in accordance with the technical documentation.
NOTE!
It is allowed to use another measuring instrument with the similar parameters and characteristics.
8. SAFETY MEASURES AND MAINTENANCE
Lower the grip smoothly to the stop point while closing the lid.
Keep the lid open between tests to extend lifetime of the elastic ring.
Do not expose to direct sunlight when testing the self-contained self-rescuers.
After usage wipe the chamber with clean cloth and put inserts inside.