VIDEO SYSTEM GB2 NEXA MODULAR - BUILDING
SAFETY PRECAUTIONS
- Install or modify the equipment, without the power connected.
- The installation and handling of these equipments must be performed by authorised personnel.
40 cm.
- The entire installation must be at least
- With power supply (FA-GB2/A):
w Do not use excessive force when tightening the connector screws.
w Install the power supply in a dry and protected place without risk of drip or water projections.
wAvoid to place it near to heating sources, in dusty locations or smoky enviroments.
wDo not block ventilation holes of the unit so that air can circulate freely.
wTo avoid damage, the power supply has to be firmly fixed.
wTo avoid an electrical shock, neither remove the protection cover nor handle the connected wire
in the terminals.
CHARACTERISTICS
( )
*
- Video door entry system with simplified installation (2 wire bus without polarity).
- Up to 4 access door panel (necessary DP-GB2A distributor for more than 1 door panel access) per
installation.
- Up to 23 monitors and apartments with Vesta2 monitor per installation.
- Up to 18 monitors and apartments with Thera monitor per installation.
- Up to 4 monitors per apartment.
- Acoustic call acknowledgment signal.
- Visual indications on the door panel for people with impaired hearing, indicating (call progress,
communication, door open and system busy).
-
Audible indications from the door panel for people with impaired vision
resident unavailable door is open communication is finished and system is busy
,
,
SYSTEM OPERATION
- To make a call the visitor should press the push button corresponding to the desired apartment;
an acoustic tone will be heard confirming the call is in progress once the push button has been
pressed and the led
will turn on. If the vocal synthesis is enabled the message "call is in
progress" will be heard confirming the call is in progress. At this moment the apartment's
monitor(s) receives the call. During the call the visitor can correct his call by pressing a push
button corresponding to a different apartment, in which case the original call is cancelled.
- In systems with several accesses doors, the other(s) door panel(s) will be automatically
disconnected: if a visitor tries to call from other door panel an acoustic tone will be heard and the
led
will turn on. If the vocal synthesis is enabled the message "system is busy, try later" will be
heard confirming the system is busy
- The call lasts for 40 seconds. Without alerting the visitor, their image is displayed on master
monitor to receive the call. To view the picture on a slave monitor this function must first be
activated in the monitor.
If the call is not answered within 40 seconds, the led
- To establish communication, press the push button
will turn on. If the vocal synthesis is enabled the message "you can speak now" will be heard
confirming the communication is activated.
- Communication will last for one and a half minutes or until the button
the communication has finished, the leds
vocal synthesis is enebled, the message "communication is finished" will be heard in the door
panel confirming the communication has finished.
- To open the door, press the door release push button
with one press, the door release operates for 5 seconds, the led
the vocal synthesis is enabled, the message "door is open" will be heard in the door panel.
- For the operation and configuration monitor, see the corresponding monitor manual.
( ) For more information see user manual "T632/GB2 (cod. 50121878)".
*
https://doc.golmar.es/search/manual/50121878
other installation.
away from any
, indica
ting call is in progress
(
try later).
will turn off and the system will be freed.
of any monitor to the apartment; door panel led
is pressed again. Once
and will turn off and the system will be freed. If the
during call or communication progresses:
will also turn on for 5 seconds. If
2
VIDEO SYSTEM GB2 NEXA MODULAR - BUILDING
DOOR PANEL INSTALLATION
( )
*
1650
1450
EL632/GB2
Monitor Code
ON
DIP
C. 01
1 2 3
4 5
6
ON
DIP
C. 10
1 2 3
4 5
6
ON
DIP
C. 08
1 2 3
4 5
6
,
ON
DIP
C. 06
1 2 3
4 5
6
ON
DIP
C. 04
1 2 3
4 5
6
ON
DIP
C. 02
1 2 3
4 5
6
( )
Description and adjustments:
*
- Description of the visual indications on the door panel.
- Description of the door panel led lights (low light conditions).
- Description of the vocal synthesis (audible indications from the door panel).
- Adjusting the vocal synthesis volume.
( )
Adjusting the door panel communication volume:
*
If after starting the system, the door panel audio volume seems inadequate, follow these steps:
- Call an apartment.
-The call is received in the apartment. Establish communication by pressing the
on the monitor.
- Next, press the same push button used to call the apartment for
confirmation tones are heard and the door panel comunication
- Each press on the same call push button will increase the door panel volume and the led's
blink speed.
There are 5 volume settings and the led's blink speed will vary for each Slow to fast blink -
low to high volume. fter reaching "setting 5", that is
A
next setting is "setting 1", that is minimum blink speed and volume (carousel mode).
-
To save the volume setting keep the same push button used to call the apartment pressed
until a series of confirmation tones are heard and the door panel communication l
off.
( ) For more information see user manual "T632/GB2 (cod. 50121878)".
*
https://doc.golmar.es/search/manual/50121878
Embedding box dimensions:
Modules
1
2
Model
N
CE 90C
V
S
N
CEV90C
1850
W
99
99
H
135,5
238
D
40
56
Monitor Code
ON
DIP
C. 30
1 2 3
4 5
6
ON
DIP
C. 28
1 2 3
4 5
6
ON
DIP
C. 26
1 2 3
4 5
6
ON
DIP
C. 24
Monitor Code
1 2 3
4 5
6
ON
DIP
ON
DIP
C. 22
C. 00
1 2 3
4 5
6
1 2 3
4 5
6
EL610D
ON
DIP
ON
DIP
C. 09
C. 20
1 2 3
4 5
6
1 2 3
4 5
6
ON
DIP
ON
DIP
C. 07
C. 18
1 2 3
4 5
6
1 2 3
4 5
6
ON
DIP
ON
DIP
C. 05
C. 16
1 2 3
4 5
6
1 2 3
4 5
6
ON
DIP
ON
DIP
C. 03
C. 14
1 2 3
4 5
6
1 2 3
4 5
6
ON
DIP
ON
DIP
C. 11
C. 12
1 2 3
4 5
6
1 2 3
4 5
6
led
's starts to blink.
m xim
a
um blink speed and
3
3
CEV90
99 mm.
328 mm.
56 mm.
EL610D
Monitor Code
ON
DIP
C. 29
1 2 3
4 5
6
ON
DIP
C. 27
1 2 3
4 5
6
ON
DIP
C. 25
1 2 3
4 5
6
ON
DIP
C. 23
1 2 3
4 5
6
ON
DIP
C. 31
1 2 3
4 5
6
EL610D
ON
DIP
C. 19
1 2 3
4 5
6
ON
DIP
C. 17
1 2 3
4 5
6
ON
DIP
C. 15
1 2 3
4 5
6
ON
DIP
C. 13
1 2 3
4 5
6
ON
DIP
C. 21
1 2 3
4 5
6
push button
3 se
conds until a series of
.
volume,
the
ed
turns