OPERATION
• Tum the Key to ON position
• Lower the head assembly to the floor by stepping on
the foot pedal and disengage it
• Lower the squeegee assembly by lowering the squeegee
assembly lever
• Press vacuum ON/OFF button to turn on the vacuum
• Press Brush ON/OFF button on to turn on the brush
• the machine is ready to use
• Raise the head assembly from the
floor by stepping on the foot pedal
and engage it
• Raise the squeegee assembly by
raising the squeegee lever
MACHINE STORAGE
• Store the machine indoor in a dry location
• Always store the machine with the squeegee and
pad/driver raised off the floor
• Always drain the solution and recovery tank fully
before storing, especially when storing in a cold
location
Troubleshooting
Problem
No power
Little or no
solution flow
Poor water pickup
18" Electric Auto
Floor Scrubber
• Adjust the water flow
with the water flow lever
• When finished, turn off
Water
both brush and vacuum
Flow
Lever
buttons
Engaged
Cause
Unit not plugged in.
Open circuit breaker.
Water flow tap closed.
Clogged solution tank filter.
Empty solution tank.
Squeegee clogged.
Squeegee blades worn.
Squeegee not mounted correctly.
Vacuum hoses have a hole or are loose.
Vacuum hose may be clogged.
Drain hose stopper is loose.
Recovery tank is open.
Recovery tank is full.
Float shut off is clogged.
Vacuum motor is loose.
MAINTENANCE
Daily Maintenance
• Wipe the whole machine with clean/damp cloth
• Empty the solution tank by opening solution drain plug
location on the bottom
• Drain and rinse out recovery tank with clean water.
• Clean the vacuum filter by removing the vacuum intake
cap
• Remove the Pad Driver/Brush and Squeegee assembly
and Clean with clean water
Monthly Maintenance
• Flush out solution tank with clean water.
• Remove the clear cap by turning counter-clockwise
and remove the filter. Clean the filter with clean water.
• Clean rubber skirt on the brush head assembly by
removing the spring lock.
• Motors should be checked every 250 hours. Turn on/
off both pad/brush and vacuum motor to ensure the
motors are working properly.
Pedal
Squeegee Rubber Blade Replacement
• Remove the squeegee assembly from the unit (refer to
squeegee assembly installation).
• Unlock the spring lock and slide out the blades.
• Replace with new blade and reassemble.
Clean debris from squeegee with damp towel.
Confirm that the squeegee assembly is securely fastened
Check hose connections and make sure they are firm.
Check hose for debris and remove any clogs.
Confirm the clear recovery tank lid is securely in place.
Remove float shut off from inside recovery tank and
Tighten vac motor mounting screws. DO NOT over tighten
4
Solution
Plug in the unit.
Turn on circuit breaker.
Open water flow tap.
Clean solution tank filter.
Fill the solution tank.
Install new squeegee blades.
to the machine and not loose fitting.
Replace hose if damaged.
Tighten drain plug.
Drain recovery tank.
remove any debris.
or damage will occur
User's Manual
User's Manual
User's Manual