11
11A
11B
11 SIDE SPRAY INSTALLATION
Insert Side Spray Hose (11A) through Hose Guide (11B).
12
12 SOAP DISPENSER INSTALLATION
Pour in liquid soap (not included) into Shank Orifice (12A). Insert Pump
Mechanism (12B) into Soap Dispenser Shank (12C). Install Dispenser Head
(12D) by pushing firmly onto Pump Mechanism (12B).
ENGLISH
12D
12B
12A
12C
4
13
13B
13A
13C
13C
13D
13 DIVERTER INSTALLATION
Push Diverter Tee (13A) all the way up until completely seated onto Mounting
Shank (13B). Slide Clip (13C) into Diverter Holes (13D), to secure unit.
When installing without side spray, a One Way Connector (13E) 970-037 must
be used and is to be ordered separately.
14
14D
14B
14C
14B
14A
14D
14C
14 HOSE ATTACHMENTS
From underneath sink, push Outlet Hose Fitting (14A), firmly onto the Diverter
Receiving Tube (14B) until unable to push any further. Connect Spray Hose
Fitting (14C) into Diverter Outlet Collet (14D) until unable to push any further. Pull
out on connection Fittings (14A & 14C). If the Fittings (14A & 14C) and the Inner
Collets (14E) separate slightly but do not pull off, the connections are secure.
13E
14A
14A
14E
14C