INSTALLATION
WARNING: The installation and assembly of electrical equipment must be carried out
by an authorised installer.
- Remove the bottom drawer, open the top cover and insert the conductors thought
the drill hole provided for this purpose.
- Connect the conductors to the terminal strip following the scheme: Terminal 1:
appliance earth connection. Terminals 2 and 3: power supply, marked L (live) and
N (neutral). Terminals 4 and 5: timing circuit (potential-free).
1
2
L
The appliance is internally protected from interference by means of a safety circuit.
Nevertheless, some especially strong electromagnetic fields may affect its operation.
Interferences may be avoided if the following installation instructions are followed:
- The appliance should not be installed close to inductive loads.
- It is advisable to provide a separate line for the power supply (if necessary
provided with a network filter).
- Inductive loads must be provided with interference suppressors (varistor, RC
filter).
PROGRAMMING
IMPORTANT: PROGRAMMING MUST BE CARRIED OUT WITH THE APPLIANCE
DISCONNECTED FROM THE MAINS VOLTAGE.
All the programming is carried out by means of the device situated below the display.
To access this it will be necessary to pull out the coin drawer, remove the two screws
that fasten the top cover and remove this.
The programming device consists of 6 mini-switches numbered 1 to 6 from left to
right. Switches 1, 2, 3 and 4 configure a timing value, as shown in the following table,
and switch 5 defines the value as hours or minutes (ON = hours, OFF = minutes).
Switch 6 has no function.
TIMING (SEE TABLE)
ON
1
2
POSITION
VALUE
1
2
3
4
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
DESCRIPTION
DISPLAY: Indicates the number of coins until the end of timing.
PAUSE: Timing may be temporarily stopped without loss of memory by disconnecting
the CTME power supply. When the CTME is reconnected the countdown will continue
where it left off.
EARLY WARNING: The display will start to flash one minute before the expiry of the
time corresponding to the last coin.
"CTME BÁSICO" PROGRAMMING EXAMPLES
Example A
1 = OFF
ON
2 = ON
3 = OFF
4 = ON
5 = OFF
CTME BASICO
COIN OR TOKEN OPERATED TIME METER
3
4
5
N
TIMING
HOURS
POSITION
3
4
5
6
MINUTES
POSITION
POSITION
VALUE
1
2
3
4
1
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
2
3
OFF
ON
OFF
ON
4
ON
ON
OFF
ON
5
OFF
OFF
ON
ON
6
ON
OFF
ON
ON
7
OFF
ON
ON
ON
8
ON
ON
ON
ON
15 MINUTES PER COIN
Example B
Example C
TECHNICAL FEATURES
- Nominal voltage:
- Frequency:
- Breaking power:
- Own consumption:
- Precision:
- Memory reserve without power:
- Temperature range. Operating conditions:
- Casing protection:
- Maximum number of coins or tokens:
- Timing by coin or token
- Coin types. Only one of the following types:
DIMENSIONS
9
10
15
20
30
45
90
150
30 MINUTES PER COIN
1 = OFF
ON
2 = OFF
3 = ON
4 = ON
5 = OFF
1 HOUR PER COIN
1 = OFF
ON
2 = OFF
3 = OFF
4 = OFF
5 = ON
- Maximum:
- Minimum:
145.2
ORBIS TECNOLOGÍA ELÉCTRICA, S.A.
Lérida, 61
Teléfono:+ 34 91 5672277;
E-mail:
http://www.orbis.es
See rating plate
50 Hz
10 A – 2A X 250 V~
5 VA
±0.2%
1 year
-10°C to +45°C
IP 20 to UNE 20-324
9 (Recognises up to 255)
150 hours/coin
1 minute/coin
0,50€, 1€ and 2€