S W A N C A M
DETECTOR PIR Y CAMARA MONO/COLOR CON INMUNIDAD ANIMALES
CONFIGURANDO EL DETECTOR
CONFIGURANDO INMUNIDAD ANIMALES
Interruptor 1 del dipswitch DIP5, usado para
configurar la función de inmunidad animales – desde
15 hasta 25Kg dependiendo del tamaño del animal
Posición arriba -ON – Inmunidad animales hasta 15 kg
Posición abajo - OFF – Inmunidad animales hasta 25
kg
AJUSTE DEL PULSE PIR
Interruptor 2 del dipswitch DIP5, usado para
configurar la función PULSE para proveer de control
de sensibilidad al PIR acorde al ambiente.
Posición arriba – ON – Sensibilidad alta
Para ambientes estables.
Posición abajo – OFF – Sensibilidad baja
Para ambientes duros.
AJUSTE DEL LED
Interruptor 3 del dipswitch DIP5, usado para
configurar el LED.
Posición arriba - ON – LED Activo, El LED se activa
cuando hay una condición de alarma..
Posición abajo – OFF - LED Desactivado, El LED
permanece desactivado.
Nota: el estado del interruptor "LED" no afecta al
funcionamiento del rele.
Cuando un intruso es detectado, el LED se activa y el
rele se activa durante 2 segundos en condición de
alarma.
BLOCK
CONNECTOR
SWITCH
FOR
SETTINGS
PIR
SENSITIVITY
ADJUSTMENT
TAMPER
PYROSENSOR
Fig.5
CROW ELECTRONIC ENGINEERING LTD. ("Crow") - WARRANTY POLICY CERTIFICATE
This Warranty Certificate is given in favor of the purchaser (hereunder the "Purchaser") purchasing the products directly from Crow or from its authorized distributor.
Crow warrants these products to be free from defects in materials and workmanship under normal use and service for a period of 1 year from the last day of the week and
year whose numbers are printed on the printed circuit board inside these products (hereunder the "Warranty Period").
Subject to the provisions of this Warranty Certificate, during the Warranty Period, Crow undertakes, at its sole discretion and subject to Crow's procedures, as such
procedures are form time to time, to repair or replace, free of charge for materials and/or labor, products proved to be defective in materials or workmanship under normal
use and service. Repaired products shall be warranted for the remainder of the original Warranty Period.
All transportation costs and in-transit risk of loss or damage related, directly or indirectly, to products returned to Crow for repair or replacement shall be borne solely by the
Purchaser.
Crow's warranty under this Warranty Certificate does not cover products that is defective (or shall become defective) due to: (a) alteration of the products (or any part
thereof) by anyone other than Crow; (b) accident, abuse, negligence, or improper maintenance; (c) failure caused by a product which Crow did not provide; (d) failure
caused by software or hardware which Crow did not provide; (e) use or storage other than in accordance with Crow's specified operating and storage instructions.
There are no warranties, expressed or implied, of merchantability or fitness of the products for a particular purpose or otherwise, which extend beyond the description on
the face hereof.
This limited Warranty Certificate is the Purchaser's sole and exclusive remedy against Crow and Crow's sole and exclusive liability toward the Purchaser in connection
with the products, including without limitation - for defects or malfunctions of the products. This Warranty Certificate replaces all other warranties and liabilities, whether
oral, written, (non-mandatory) statutory, contractual, in tort or otherwise.
In no case shall Crow be liable to anyone for any consequential or incidental damages (inclusive of loss of profit, and whether occasioned by negligence of the Crow or
any third party on its behalf) for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Crow does not represent that
these products can not be compromised or circumvented; that these products will prevent any person injury or property loss or damage by burglary, robbery, fire or
otherwise; or that these products will in all cases provide adequate warning or protection.
Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of burglary, fire, robbery or other events occurring without
providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result.
Consequently, Crow shall have no liability for any personal injury; property damage or any other loss based on claim that these products failed to give any warning.
If Crow is held liable, whether directly or indirectly, for any loss or damage with regards to these products, regardless of cause or origin, Crow's maximum liability shall not
in any case exceed the purchase price of these products, which shall be the complete and exclusive remedy against Crow.
P/N 7101574 REV. A Y.S - A.Y.
CONFIGURANDO EL TIEMPO DE RELE N.O.
Interruptores 4 & 5 del dipswitch DIP-5 usado para
configurar el tiempo de retardo de los contactos N.O.
del rele terminales 6 y 7.
Estos tienen cuatro opciones.
Interr
interr
4
5
ON
ON
ON
OFF
OFF
ON
OFF
OFF
El contacto N.C. (Terminales 5 y 6) cuando hay una
alarma quedan abiertos de 1.8 – 2 sec..
AJUSTE SENSIBILIDAD PIR
Use el potenciómetro marcado "PIR" para ajustar la
sensibilidad del detector entre 15% y 100% de
acuerdo al test de andado.
(Configuración de fabrica 57%).
Gire el potenciómetro en el sentido de las agujas del
reloj para incrementar el alcance, y a la inversa para
disminuir el alcance.
AJUSTE SENSIBILIDAD AUDIO
Use el potenciómetro "AUDIO" para ajustar la
sensibilidad del audio.
Gire en el sentido de las agujas para incrementar la
sensibilidad.
Gire el potenciómetro a la inversa de las agujas del
reloj para disminuir la sensibilidad.
OPCIONES DE SOPORTE DE INSTALACION
Soporte de techo
CAMERA
INPUT
AUDIO
SENSITIVITY
ADJUSTMENT
ESPECIFICACIONES TECNICAS
Tipo cámara
Elementos imagen
Resolucion
RETARDO TIEMPO N.O.
2 Seg. Contacto cerrado
Sensivilida
15 Seg. Contacto cerrado
(NTSC; PAL)
60 Seg. Contacto cerrado
240 Seg. Contacto cerrado
S/N Ratio
Electronic Shutter
Time
Salida video
Método detección
Alimentación
Consumo
Color: 150 mA
Compensacion
temperatura
Periodo alarma
Salida alarma
Tamper
Periodo espera
Indicador LED
Dimensiones
Soporte pared
Peso
CROW ELECTRONIC ENGINEERING LTD.
ISRAEL:
USA:
AUSTRALIA:
SPAIN:
LATIN AMERICA:
ITALY:
These instructions supersede all previous issues in circulation prior to October 2004.
- 2 -
INSTRUCCIONES DE INSTALACION
B&W:
CCIR o EIA
COLOR: PAL o NTSC
290K (PAL; CCIR) 250K
(NTSC;EIA)
420 TV lineas (PAL; NTSC)
380 TV lineas (CCIR; EIA)
0.5Lux - F2.0
0.5Lux - F1.2 (EIA; CCIR)
Mejor que 48 dB
1/60 – 1/100,000 sec
(NTSC; EIA)
1/50 – 1/100,000 sec
(PAL; CCIR)
1V p-p 75Ω
Quad (Cuatro) elementos PIR
8.2 to 16 Vdc
Mono:
115 mA
SI
2 +/- 1 sec
N.C 28Vdc 0.1 A con
10Ohm proteccion
N.C 28Vdc 0.1A con
10 Ohm protección
Activación por apertura
1 min
LED rojo encendido en alarma
123mm x 61mm x 38mm
135 gr.
N345
57 Hamelacha St., Holon 58855
Tel: 972-3-5569937 /8 /9
Fax: 972-3-5592981
E-mail:
support@crow.co.il
2160 North Central Road,
Fort Lee, N.J. 07024
Tel: 1-800-GET CROW
or
(201) 944 0005
Fax: (201) 944 1199
E-mail:
support@crowelec.com
429 Nepean HWY Brighton East Vic 3187
Tel: 61-3-9596 7222
Fax: 61-3-9596 0888
E-mail:
crow@crowaust.com.au
by Demes, S.L..
San Fructuoso, 50-56.
08004-Barcelona España
Tel: (34) 934 254 960
Fax: (34) 934 261 904
E-mail: bydemes@bydemes.com
CROW LATIN AMERICA
ST
5753 NW 151
.Street
MIAMI LAKES,
FL 33014 – USA
Tel: +1-305-823-8700
Fax: +1-305-823-8711
E-mail:
sales@crowlatinamerica.com
DEATRONIC
VIA Giulianello 4/14
00178 ROMA, ITALY
Tel: +39-0676-12912
Fax: +39-0676-12601
E-mail:
info@deatronic.com