Led Indication; Hysteresis Mode; Auto Hysteresis Value; Cutoff Distance - CARLO GAVAZZI IO-Link PD30CTB Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 129

2.5.13. LED indication

The LED indication can be configured in 3 different modes: Inactive, Active or Find my sensor.
Inactive: The LEDs are turned off at all times
Active: The LEDs follow the indication scheme in 5.1.
Find my sensor: The LEDs are flashing alternating with 2Hz with 50% duty cycle in order to easily locate
the sensor.

2.5.14. Hysteresis mode

See 2.4.1.3. Hysteresis Settings

2.5.15. Auto hysteresis value

See 2.4.1.3. Hysteresis Settings

2.5.16. Cutoff distance

Range 20...250 mm for PD30CTBx20..., 20...300 mm for PD30CTBS25... and 20 ... 400 mm for PD30CTBR35...
Measured distance beyond Cutoff distance, will be truncated to Cutoff distance.
Cutoff distance value will also be used when an object cannot be detected.
27
Rev.00 - 06 .2021 | MAN PD30CTB IO-Link EN | © 2021 | CARLO GAVAZZI Industri

Publicidad

Tabla de contenido
loading

Tabla de contenido