Berker 7590 00 57 Instrucciones De Mando Y De Montaje página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB
Specifications
Power supply
Sensor unit (incl. heating)
: 24 V AC/DC ± 15%, 50/60 Hz
Max. current consumption
: 600 mA
Power consumption
: 14.4 W max. (sensors and heating)
Weather station current loading : max. 28 mA
Connection
Connecting cable
: LiYCY, 6 x 0.25 mm
Length
: 10 m, max. 50 m
Ambient conditions
Ambient temperature
: -40 °C ... +60 °C, no icing *)
Storage/transport temperature : -40 °C ... +60 °C
Humidity
: outside the building
Enclosure
Protective system
: IP 55 in working position as per EN 60529
Protection class
: III
Dimensions (diameter x height) : 130 x approx. 200 mm
Type of installation
: stainless steel bracket on mast or wall
Weight
: approx. 330 g
Sensor signals
Wind velocity
Measuring range
: 1 ... 40 m/s
: ≤ 0.5 m/s, -20 °C ... +60 °C
Accuracy
Precipitation
Measuring range
: precipitation yes/no
Sensitivity
: fine drizzle
Switch-on delay
: approx. 3 precipitation particles
Switch-off delay
: approx. 2 minutes
Brightness
Measuring range
: approx. 0 ... 110 kilolux
Spectral range
: approx. 700 ... 1050 nm
Resolution
: 10 bits
Cardinal points
: East, South, West
Twilight
Measuring range
: approx. 0 ... 674 lux
Resolution
: 10 bit
*) „no icing" means no frozen rain on
a) moving parts or sensors b) light-sensitive elements or sensors
14
Combination sensor
2
, shielded
Combination sensor
Guarantee
We reserve the right to make technical and formal changes to the product in the
interest of technical progress.
Our products are under guarantee within the scope of the statutory provisions.
If you have a warranty claim, please contact the point of sale or ship the device
postage free with a description of the fault to the appropriate regional representative.
GB
15

Publicidad

Tabla de contenido
loading

Tabla de contenido