LIGHTING AND SHUT-DOWN
Lighting the Heater:
appliance rating plate for the correct fuel information.
2.
Turn off the main gas supply to the appliance. Wait five
minutes.
3.
Turn on the main gas supply.
6.
IMPORTANT: DO NOT attempt to adjust the main
burner input using the main gas supply valve, as this
may cause the thermocouple to shut down the burner.

Shut-down instructions:

3.
If the heater is not going to be used for an extend period
of time disconnect the regulator/hose assembly from the

MAINTENANCE INSTRUCTIONS

evidence of excessive abrasion or wear, or if the hose is cut, it
must be replaced prior to the heater being put into operation.
The replacement hose assembly shall be that specified by the
manufacturer. See the parts list.
materials, gasoline and other flammable vapors and liquids at all
times.
The flow of combustion and ventilation air must not be
obstructed.
Cleaning the heater:
Periodically, the heater must be cleaned of all dirt and dust
particles.
DANGER
DO NOT ATTEMPT TO CLEAN THE HEATER
WHILE IT IS OPERATING OR WHILE IT IS
STILL HOT.
clean the heater by spraying water on it. Wipe the outside of
the heater off with a dry cloth after cleaning.
forth along the entire burner face to dislodge dust and debris
from the ceramic tiles. Using an OSHA appoved blow gun,
blow compressed air through venturi from the control end of
the heater.
DO NOT operate this heater if any part has been under
water. Call a qualified service person to inspect the appliance
and to replace any part of the control system or gas control valve
which has been under water.
This heater must be inspected at least annually by a qualified
service person.