Safety measures:
1. Do not lift or descend an unloaded hoist.
2. Do not wash the cables with water or corrosive detergents. Otherwise the cables
corrode and as a result may be destroyed.
З. When cleaning lighting fixtures regularly check for any corrosive stains and cable
deteriorations. Cable deteriorations may lead to cable breaking and falling of a
fixture.
4. To prevent corrosion after cleaning the lighting fixture cover the cables with anti-
corrosive rust cement.
б. It is forbidden to use hoist in industrial purposes and to suspend loads
other than lighting fixtures.
7. It is strictly forbidden to hoist a powered-on lighting fixture!
FORBIDDEN to rotate the lighting fixture mounted on the hoist. Rotation
can lead to permanent hoist (cable and mechanisms) and lighting damage.

Technical specifications

Table 1. Technical characteristics
Product
Hoist
Decorative cover
model
dimensions
diameter, mm
(L*W*H)
Ø min-320
Lift MW-50
320*320*60
Ø max-530
h-60
Ø min-320
Lift MW-100
320*320*60
Ø max-530
h-60
Ø min-350
Lift MW-150
350*350*80
Ø max-525
h-80
Ø min-450
Lift MW-250
450*450*110
Ø max-530
h-110
EN
16
Nominal carrying
Weight
Maximum
load (kg)
(kg)
lifting
height (m)
50
8
4
100
14
5
150
14
6
250
25
6
Decorative cover
Table 2. Key technical parameters
Product
Maximum capacity
model
(kW)
Lift MW-50
Lift MW-100
6
Lift MW-150
Lift MW-250

Main components

Сomponents supplied in the package
Power cable section
Power
(mm2)
supply
2,5 х 2
Ас 220V +/- 10 V 50/60 Hz
Hoist
Anchor bolt
17
EN