7 | ACT925 Operators Manual

Product Specifications

Model No.
Name
Sensitivity
Sensor Life
Response Time
Power Supply
Battery Life
Warm up time
Probe length
Weight, lbs
Warranty

EN14624/2012 Test Specifications

Minimum/Maximum
Sensitivity Threshold (fixed)
Minimum/Maximum
Sensitivity Threshold
(moving)
Minimum Detection Time
(1gm/yr)
Clearing Time
Minimum Threshold after
Maximum Exposure
Sensitivity Threshold in
Polluted Atmosphere
Calibration Frequency
ACT925 Operators Manual | Version 1.0 | Nov. 2019
ACT925
Leak Detector, Refrigerant Gas
.05 oz/yr R134a, .0123 oz/yr R1234yf
> 10 years
Instantaneous
4 AA Alkaline batteries
4 hours continuous
< 20 seconds
17 inches
1.5 lbs
2 years (includes sensor)
1 gm/yr minimum, >50 gm/yr
maximum
2 gm/yr minimum, > 50 gm/yr
maximum
Approx 1 sec
Approx 9 seconds after exposure
to >50 gm/yr
1 gm/yr
1 gm/yr
1/yr check with calibrated leak
Standard
Snap-on Tools