Descargar Imprimir esta página

Titan Controls Zephyr 2 Guía Sencilla

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

®
Zephyr 2
High Temperature Shut Off Thermostat
Easy Guide
Notes: This unit has been set to perform 10°F cooldown.
For 5° cooldown, refer to Optional settings.
VANCOUVER, W ASHINGTON U.S.A.
INSTRUCTIONS – REV. C
High
temp
Step 1
Set 'High Temp' and
'start delay' values
HOLD RESTART
After Shut-OFF, the
unit will not restart
when knob is set
to HOLD RESTART.
OPTIONAL SETTINGS
B
A
C
Change to 5°F cool down
A. Set both values to maximum
B. Plug in, then set both values to minimum within 5 seconds
C. Output light turns on or off according to actual setting
D. Follow instructions as shown in Step 1 & 2
Helios 4
240 Volt
Start
delay
Step 2
Plug into 120VAC outlet
Connect the relay trigger cord set from lighting
controller into the front panel outlet
Note: If Zephyr 2 is plugged into a 24h timer, deduct start delay
from timer start program (start time).
Installation is now complete
B
Change to 10° cool down
A. Set both values to minimum
B. Plug in, then set both values to maximum within 5 seconds
C. Output light turns on or off according to actual setting
D. Follow instructions as shown in Step 1 & 2
www.titancontrols.net
For technical assistance call us at
1-888-80-Titan or 1-888-808-4826.
Sensor
A
B
C
®

Publicidad

loading

Resumen de contenidos para Titan Controls Zephyr 2

  • Página 1 Connect the relay trigger cord set from lighting HOLD RESTART controller into the front panel outlet After Shut-OFF, the Note: If Zephyr 2 is plugged into a 24h timer, deduct start delay unit will not restart from timer start program (start time). when knob is set to HOLD RESTART.
  • Página 2 REINICIO controlador de iluminación al tomacorriente del panel delantero Después de Nota: Si el Zephyr 2 se enchufa en un temporizador de 24 horas, apagarse, la unidad reste el retardo de inicio del programa de inicio de temporizador no se reiniciará...