TECHNICAL DATA / INSTALLATION JOLLY 20/6

TECHNICAL DATA

Max gate weight
Max gate surface
Limit switch winding capacity
Nominal functioning torque
Max operating torque
Max lifting force from earth
Max operating force
Pulley revolutions
Pulley diameter
Shaft diameter
EEC Power supply
Motor capacity with load
Power absorbed with load
Capacitor
Functioning cycles
Daily operations suggested
Service
Nominal functioning time
Motor weight
Working Temperature
Protection grade
*
The condenser is bound to the motor with a rubber band. Please remove the rubber band and fix the condenser to the rolling shutter post with the two bands in equipment.
R
OLLING GATE CONTROL
The European Standard EN 12604 "Industrial, Commercial and Garage Doors
and Gates - Mechanical Aspects - Requirements", at the point 4.3. "Protection
against unintentional and uncontrolled movements" requires also that*:
a - The vertically operating door leaves shall be balanced so that the door
leaf can stop in any position, or that the out-of-balance state shall not
produce, in any case, a static force at the primary closing edge of the
door exceeding 150N (15,3 kg / 33,70 lbs).
Verify it after having manually released the JOLLY 20/6 operator.
b - If a spring fails, the resulting out-of-balance static force occurring
at the primary closing edge of the roller shutter shall not exceed
200N (20,4 kg / 44,94 lbs), even when the JOLLY 20/6 operator is
manually released. After this failure, you must intervene on the door to
substitute the broken spring and correct the balance state. Therefore,
we suggest you to fraction the roller shutter weight with an adequate
number of springs (* This is a free interpretation).
WARNING: The EN 12445 standard "Industrial, commercial and garage
doors and gates - safety in use of power operated doors - test methods"
at point 4.1.2 "safeguarding against hazard of being lifted" provides that
the rolling gate shall not be able to lift more than 20 kg / 44 lbs.
In order to meet this standard, RIB suggests to install the control board
with electric power regulation J-CRX (cod. ABJ7080).
332/13
Measurements in mm/inch
kg
2
m
N° rotat.
Nm
Nm
kg
kg
rpm
mm
mm
W
A
µF
s
kg
°C
IP
PARTS TO INSTALL MEETING THE EN 12453 STANDARD
COMMAND TYPE
(out of a public area*)
with manned operation
with visible impulses
(e.g. sensor)
with not visible impulses
(e.g. remote control device)
automatic
* a typical example are those shutters which do not have access to any public way.
A: C ommand button with manned operation (that is, operating as long as activated),
like code ACG2012.
B: Key selector with manned operation, like code ACG1010.
C: Motor force regulation.
D: S afety edges or Sensor able to detect an obstacle and/or other safety devices to
keep thrust force within the limits of EN12453 regulation - Appendix A.
E: P hotoelectric cells, eg. code ACG8026 (To apply on the whole height of the door
up to max 2,5 m as indicated on EN 12445 point 7.3.2.2).
I
N ORDER TO ENSURE A CORRECT FUNCTION ONLY
RIB'S COMPONENTS MUST BE USED
1 - JOLLY 20/6 operator
2 - Photoelectric cells (external)
3 - Push-Button
1
1
1
1
JOLLY 20/6
220
16
8,5
120
100
120
100
13
200
60
230V~50/60Hz
120V~60Hz
850
3,8
25
7 - 20s/2s
5 - 20s/2s
20
30%
330
7
-10 ÷ +70
30
USE OF THE SHUTTER
Skilled persons
Skilled persons
(public area)
A
B
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
4 - Key selector
5 - Tuned aerial
6 - Flashing lamp
890
7,8
*
90
Unrestricted use
-
C and D, or E
C and D, or E
C and D, or E