Detection Range Settings (Sensitivity); Timer Settings; Light Control Settings; Problems And Solutions - shada 240120X 01 Manual De Usario

Lumenaria resistente al agua con sensor de movimiento hf
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

-

Detection range settings (sensitivity)

Detection range is the radius of the circular detection zone after mounting the
sensor at a height of 2,5m. Turn the detection control fully anticlockwise to select
minimum detection range (approx. 2m radius), and fully clockwise to select maxi-
mum detection range (approx. 16m radius).
Note: The HF sensor scanning specifications may vary slightly depending on the
mounting height and location.
SENS
TIME
Attention: When using this product, please do not adjust the sensitivity to ma-
ximum. Factors like blowing leaves or small animals can cause the product to turn on. If the
product does not function properly, please lower the sensitivity settings.
-

Timer settings

The light can be set to stay on for any period of time between 10 seconds (dial
turned fully anti-clockwise) and a maximum of 30 minutes (dial turned fully
clockwise). Any movement detected during the "on" time will reset the timer. The
LED indicator will flash when adjusting the time setting dial. The number of flas-
hes means the following:
1 flash = 10 seconds, 2 flashes = 1 minute, 3 flashes = 2 minutes, 4 flashed = 5 minutes, 5
SENS
TIME
flashed = 8 minutes, 6 flashes = 10 minutes, 7 flashes = 15 minutes, 8 flashes = 20 minutes, 9
flashes = 25 minutes, 10 flashes = 30 minutes
-

Light control settings

The chosen light response threshold can be anywhere between 10-2000 lux. Turn
the dial anti-clockwise to select dusk to dawn operation at 10 lux. Turn the dial
fully clockwise to select daylight operation at 2000 lux. The dial must be turned
fully clockwise when adjusting and testing the detection zone.
Note: please do not adjust the three dials past their maximum, as this will dama-
TIME
LUX
ge the product.

18 Problems and solutions

The light does not switch on
The light is on all the time
The light will go on without
any visible movement
LUX
LUX
Wrong light-control setting
selected
Broken light
Main switch is OFF
Continuous movement in
the detection zone
The sensor is not mounted
for detecting movement
reliably
Check and adjust settings
Change light
Switch ON
Check zone setting
Securely mount the sensor
8

Publicidad

Tabla de contenido
loading

Tabla de contenido