Install the Remote Transformer
1A
1
SMALL SCREW
1
Loosen (do not remove) the two small screws on the
terminal block cover. Remove the cover.
1B
HIGH VOLTAGE SIDE
LOW VOLTAGE SIDE
2
Press and hold the "Press" button on the line voltage
side and pull it apart from the low voltage side.
1
TERMINAL
BLOCK COVER
2
1C
LINE VOLTAGE WIRES
(Min 18AWG)
Note: This transformer does not require connection to
a supply ground wire to insure safe operation. It is
manufactured using a polymeric enclosure that
provides complete isolation. If using three conductor
supply wires, please sever the ground conductor
cleanly so it terminates in the transformer wiring
compartment.
3
Loosen the two screws on the terminal block.
Bring properly sized supply wires (min 18AWG) to
4
transformer.
Connect the hot and neutral 120V power line wires
5
into the 120V terminal block of the transformer.
Re-tighten the screws on the terminal block.
6
1D
SMALL
SCREW
7
7
TERMINAL
BLOCK COVER
Re-install the terminal block cover and secure it with
7
the two small screws.
Re-connect the high voltage side to the low voltage
8
side.
2
4
6
6
TERMINAL BLOCK
HIGH
VOLTAGE SIDE
LOW