ART. 09/08535-00
Resistance and Continuity Measurements
1. Insert the black test lead into
the negative COM terminal
and the red test lead into the
positive terminal.
2. Set the function switch to the
•))) Ω position.
3. Use the multifunction MODE
button to select resistance.
4.
Touch
the
test
probe
tips across the circuit or
component under test. It is
best to disconnect one side
of the device under test so
the rest of the circuit will not
interfere with the resistance reading.
5. For Resistance tests, read the resistance on the LCD display.
6. For Continuity tests, if the resistance is < 100°, a tone will sound.
Diode Measurements
1. Insert the black test lead banana plug into the negative COM
jack and the red test lead banana plug into the positive diode
jack.
2. Turn the rotary switch to the
3. Press the MODE button until "
4. Touch the test probes to the diode under test. Forward voltage
will indicate 0.4V to 0.7V. Reverse voltage will indicate "OL".
Shorted devices will indicate near 0mV and an open device will
indicate "OL" in both polarities.
Red
Black
Probe
Probe Probe
Forward test
Capacitance Measurements
WARNING: To avoid electric shock, disconnect power to the
unit under test and discharge all capacitors before taking any
capacitance measurements. Remove the batteries and unplug
the line cords.
1. Set the rotary function switch to the cap position.
2. Insert the black test lead banana plug into the negative (COM)
jack. Insert the red test lead banana plug into the positive (V) jack.
3. Touch the test leads to the capacitor to be tested.
4. Read the capacitance value in the display
Frequency or % duty cycle measurements
1. Set the function switch to the V position.
2. Insert the black lead banana plug into the negative COM jack and
the red test lead banana plug into the positive V jack.
3. Select Hz or % duty with the Hz/% button.
4. Touch the test probe tips to the circuit under test.
5. Read the frequency on the display.
Temperature Measurements
WARNING: To avoid electric shock, disconnect both test
probes from any source of voltage before making a temperature
measurement.
1. Set the function switch to TEMP.
ELCART DISTRIBUTION SPA via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY
Tel. ++39 02.25117310 Fax ++39 02.25117610 sito internet: www.elcart.com
La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.
The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product.
La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto.
ELCART
servizio automatico documentazione tecnica
N o
Y e s
.
.
¦ ¸
¦ ¸
C A P
C A P
.
n
A
D C
+
D C
A C
A C
£ ¡
•))) position.
" appears in the display.
Black
Red
Probe
Reverse test
2. Insert the Temperature Probe into the negative (COM) and the V
jacks, making sure to observe the correct polarity.
3. Select °C or °F with the MODE button.
4. Touch the Temperature Probe head to the part whose temperature
you wish to measure. Keep the probe touching the part under test
until the reading stabilizes (about 30 seconds).
5. Read the temperature in the display. The digital reading will
indicate the proper decimal point and value.
WARNING: To avoid electric shock, be sure the thermocouple has
been removed before changing to another measurement function
.
n
A
+
Data Hold and Backlight
£ ¡
To freeze the LCD meter reading, press the data hold button.
The data hold button is located on the left side of the meter (top
button). While data hold is active, the HOLD display icon appears
on the LCD. Press the data hold button again to return to normal
operation.
Note: The HOLD feature will activate when the Backlight is
turned on. Press the HOLD key again to exit Hold.
The backlight function illuminates the display and is used when the
ambient light to too low to permit viewing of the displayed readings.
Press the
(HOLD) button for one second to turn the backlight on
and press the button a second time to turn the backlight off.
Manual Ranging
The meter turns on in the autoranging mode. Press the Range
button to go to manual ranging. Each press of the range button
will step to the next range as indicated by the units and decimal
point location. Press and hold the Range button for two seconds to
return to autoranging. Manual ranging does not function in the AC
Current, Diode and Continuity check functions
Battery Replacement
1. Remove the one rear Phillips head screw
2. Open the battery compartment
3. Replace the Requires one "9V" battery (NEDA1604, 6F22 006P)
4. Re-assemble the meter
User information ex art. 26 D. 49/2014
The symbol labelled on the appliance (Annex IX D. 49/2014) indicates that
the rubbish is subject to "separate collection" and it has been placed on the
Italian market after the December 31, 2010.
The user must therefore assign or (have collected) the rubbish to a
treatment facility according to indications by the local administration, or
hand it over to the reseller in exchange for an equivalent new product. The
separate collection of the rubbish and the subsequent treatment, recycling
and disposal operations encourage the production of appliances made
with recycled materials and reduce negative effects on health and the
environment caused by improper treatment of rubbish.
In the case of very small WEEE (no external dimension more than 25 cm),
the user is eligible to get free of charge assignation to retail shops with sales
areas relating to EEE of at least 400 m².
IMPORTED AND DISTRIBUTED BY:
ELCART DISTRIBUTION SPA
Via Michelangelo Buonarroti, 46
20093 COLOGNO MONZESE (MI)
ITALY
www.elcart.com - info@elcart.it
e-mail: info@elcart.it
PAGINA 6 DI 9
Made in China