Troubleshooting (cont.)
Faucet Troubleshooting Table
Symptoms
No water flow.
1.
2.
Low water flow.
Kohler Co.
Probable Causes
Recommended Action
A. The supply
A. Confirm the supply
stops are
stops are open.
closed.
B. Handle is in
B. Rotate the handle to the
the closed
open position. Refer to
the "Faucet Operation"
position.
section.
C. The hot
C. Confirm the supply
and/or cold
hoses are not kinked. If
supply hose
coiled, maintain an
is kinked.
inside diameter of 3"
(76 mm).
D. The outlet
D. Confirm the mounting
hose is
bracket and valve box
kinked.
are located within 10"
(254 mm) from the
faucet centerline and
within 8" (203 mm) to
13" (330 mm) above the
cabinet floor.
E. E. Battery
E. Check for a red
power is low
flashing LED on the
or exhausted.
valve box. Refer to the
"Install the Batteries"
section.
Refer to the "Cleaning
F.
One or more
F.
screens are
the Screens" section.
clogged.
A. The supply
A. Confirm the supply
stops are
stops are fully open.
partially
closed.
B. Handle is
B. Rotate the handle to the
partially
full open position.
closed.
C. The hot
C. Confirm the supply
and/or cold
hoses are not kinked or
supply hose
twisted. If coiled,
is kinked or
maintain an inside
twisted.
diameter of 3" (76 mm).