Blue Angel Pumps BSP25 Manual De Instrucciones De Operación Y Piezas página 4

Bomba de respaldo para sumideros
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions and Replacement Parts List
Installation
(Continued)
Methods 1 and 2
Install float switch at least 10-12 inch
above bottom of sump pit so that
backup unit turns on only when the
water level is higher than the normal
"on" level for main pump. Use the wire
ties provided to secure the switch to
the discharge pipe. Make sure power
wires do not interfere with float switch,
pump inlet, or main pump operation.
Backup pump must not be allowed to
run dry.
Control Box Installation
1. Attach control box to the side of
battery box as shown in Figure 3.
Place battery in box, attach red
cable to positive battery post and
black cable to negative post. Put lid
on box.
Battery box bottom
Control
box screw
Lead Wires
Control box
Figure 3
are reversed, damage to the control box
or battery could result, and warranty
will be void.
2. Place battery box within six feet of
the sump and a 115 VAC separately
fused outlet. The outlet must be
protected by a ground fault circuit
interrupter (GFCI). The area must
also be clean, dry and well-
ventilated.
3. Plug the float switch, pump and
charger into the control box. The
connections are marked on the
control box.
4. Test pump operation by filling the
sump with water while the main
pump is unplugged. If the pump
operates properly, plug the charger
into the GFCI protected outlet to
begin charging the battery.
www.blueangelpumps.com
5. Protect electrical cord from sharp
objects, hot surfaces, oil and
chemicals. Avoid kinking the cord
and replace damaged components
immediately.
Operation
Always disconnect the power
source before attempting to
install, service, relocate or
maintain the pump. Never touch sump
pump, pump motor, water or discharge
piping when pump is connected to
electrical power. Never handle a pump
or pump motor with wet hands or when
standing on wet or damp surface or in
water. Fatal electrical shock could
occur.
Risk of electrical shock! Use a
GFCI receptacle to reduce the
risk of fatal electrical shock.
Cutting the cord or plug will void the
warranty and make the pump
inoperable.
1. After installation, the backup pump
will start when the water level rises
above the depth that the primary
pump should start.
2. The control box has a DC charger
designed to shorten the recharging
time of your battery, and to prevent
overcharging. In addition, the
control box has a time delay which
keeps the pump from repeated,
short cycles when it shuts off. This
time delay feature will allow the
If cables
pump to run 20-25 seconds after the
switch reaches the off position.
3. The control box contains a multi-
colored indicator light. When AC
power is present, the light will
indicate the charging state, and not
reflect actual battery voltage,
particularly with a defective battery.
In order for the indicator light to
provide an accurate reading, steps
"a" through "d" must be followed.
Unplug main AC pump and
the charger. Risk of electrical
shock!
4. A chirping sound from the control
5. A single thirty-second tone will
4
a. After main AC pump and
charger are unplugged, a power off
alert tone will sound for 30
seconds.
b. Lift and release the float switch
to activate the backup pump.
c. When the pump stops, read the
test light:
Green: Indicates battery is
charged.
Yellow: Voltage is low,
indicating battery is partially
charged.
Red: Battery is completely
discharged or defective.
d. Plug in charger and main AC
pump.
When AC power is out, and when
pump has been running, the light
will indicate battery status.
box will accompany the red light,
indicating that the battery may
require attention or replacement.
Voltage is only an indicator of
battery condition and may not
reflect the true condition of the
battery. See Maintenance for
instruction on assessing battery
condition.
sound when power to the system is
interrupted. The unit will reset
automatically when power is
restored. A three-second tone will
sound every time the pump starts.

Publicidad