INTRODUCTION
This handbook must be consigned to the user prior to installation and commissioning of the unit.
Retain these documents for future consultation.
The Digimanager torch provides the facility to display and adjust certain welding parameters by means of the display and the buttons on the
torch.
The torch is recognised automatically when it is connected to the unit so no specific set-up is required.
CODE
NAME
D1
DISPLAY
The display shows the value of the welding parameter selected by pressing the MENU key.
Hold down the key to display in sequence the acronyms in the tables below. Release the key to display the value of the selected
S1
MENU
welding parameter.
LOCK/
Lock/unlock the key to edit the welding parameters. When L1 led illuminates the parameter value can be changed.
S2
UNLOCK
When the torch trigger is pressed or the torch is inactive for some time the edit function is automatically locked.
S3
+
The key increases the value of the selected parameter.
S4
-
The key decreases the value of the selected parameter.
L1
When it illuminates the welding parameters list can be scrolled down and parameters can be changed.
6/22
ENGLISH
IMPORTANT
D1
S1
L1
S3
DESCRIPTION
S2
S4
Digimanager