6 Commissioning
6.5 Injection unit (for BRS-FPi only)
Inflowing compressed air sucks in the anti-spatter fluid and mixes it with the compressed air flow (Venturi principle).
Recommended dwell time: approx. 1 sec.
1 Move the torch with the gas nozzle vertically over the injection nozzle.
Immersion depth for optimal injection: approx. 1 mm
The injection process is started when the corresponding 5/2 directional valve is actuated.

6.5.1 Setting the release agent manually

1
Adjusting screw
Fig. 6
Setting the release agent manually (for BRS-FPi)
WARNING
Risk of injury
Injury to the eyes by sprayed release agent.
• When adjusting the anti-spatter fluid, wear suitable protective clothing, in particular safety goggles.
1 Set the required quantity of release agent by turning the adjusting screw (1) to the right (+) or left (−).
EN - 14
1
BRS-FP/BRS-FPi
BAL.0028.0 • 2021-01-19