Setting - SICK WTF4F Instrucciones De Uso

Fotocélulas miniatura
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
7.3

Setting

8025301 / 2020-11-13 | SICK
Subject to change without notice
Dimensions in mm (inch)
6
(0.24)
4
(0.16)
2
(0.08)
0
–2
(–0.08)
–4
(–0.16)
–6
(–0.24)
0
20
40
60
80
100
120
(0.79)
(1.57)
(2.36)
(3.15)
(3.94)
(4.72)
Distance in mm (inch)
Recommended sensing range for
the best performance
Figure 5: Light spot size
Sensing range adjustment
WTF4FD-xxxxxx1xAxx
Adjustment via a potentiometer:
Clockwise rotation: Sensing range increased.
Counterclockwise rotation: Sensing range reduced.
WTF4FD-xxxxxx2xAxx
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec.).
Depending on the requirements, the potentiometer can be used for fine-tuning (without
pressing the teach-in button).
Clockwise rotation: Sensing range increased.
Counterclockwise rotation: Sensing range reduced.
The sensing range can also be adjusted using just the potentiometer.
10
50
100
(0.39)
(1.97)
(3.94)
7
COMMISSIONING
9

Publicidad

Tabla de contenido
loading

Tabla de contenido