• E nsure adequate air return into the room in compliance with existing regulations in
order to ensure proper device operation.
• I f the environment in which the product is installed also houses a fuel-operating device
(water heater, methane stove etc., that is not a "sealed chamber" type), it is essential to
ensure adequate air intake, to ensure good combustion and proper equipment operation.
• I nstall the product so that the impeller is not accessible from the air outlet side as
verified by contact with the Test Finger (test probe "B" of the norm EN61032) in
compliance with the current safety regulations.
• C eiling installation
In order to guarantee the IPX4 degree of protection against moisture in case of ceiling
installation, use the appropriate ceiling mount kit, which is not included. Use only the
rear entry hole for supply cables. If there is a possibility of condensation along the air
discharge duct, provide a drainage system to prevent condensation from discharging
into the environment through the fan.
Attention: do not mount the product on the ceiling without this kit.
• W indow installation
In case of window installation it is necessary to use the appropriate window kit, which
is not included.
Attention: do not mount the product on the window without this kit.
INTRODUCTION
ELICAL TOP (Fig. 1) is an axial fan designed to ensure air extraction in small/medium-sized
rooms such as bathrooms, toilets and kitchens.
Suitable for air discharge directly to the outside or in the presence of short linear duct
(less than 1.5m). Wall, ceiling or window installation (Fig. 2).
TECHNICAL SPECIFICATIONS
• M aterial: High quality, impact and UV-resistant ABS colour RAL 9010.
• R ear reinforcement ring to prevent sleeve deformation during installation.
• H igh efficiency aerodynamic fan with "winglet" blades to optimise quietness and efficiency.
• S ingle phase induction motor with integral thermal protection.
• M otor mounted on ball bearings that guarantee a longer product life cycle (30,000h)
and suitable for cold climates.
• T he fan is double insulated: no earth connection is required.
• S uitable for continuous or intermittent operation.
• I PX4 degree of protection.
• P ower supply 220V to 240V~ 50/60Hz.
Airflow
Static pressure
Code
m
/h max
3
VNS90
60
VNS90T
60
VNS100
88
VNS100T
88
VNS100HT
88
VNS120
175
VNS120T
175
VNS120HT
175
VNS150
330
VNS150T
330
VNS150HT
330
Power
Pa max
W max
17
8
17
8
27
8
27
8
27
8
40
14
40
14
40
14
59
24
59
24
59
24
Sound pressure
dB(A) @3m
26
26
34
34
34
40
40
40
46
46
46
5