• If the flashes are read correctly, close the upper part of the D · ENER-
GY with a slight clockwise rotation.
DEVICE RESET
The procedure to reset the device and disassociate it from the DiCE
SMART is as follows:
1. Unscrew the upper part of the D · ENERGY anticlockwise;
2. press the pairing button 7 times inside the D · ENERGY (alternating
one pulse every second).
3. the signaling LED will emit a prolonged blink (about 1 sec) followed
by 3 rapid blinks. The 3 quick blinks indicate that the device is
ready to repeat the association procedure with the DiCE SMART as
indicated in the INSTALLATION paragraph.
BATTERY LIFE
The estimated battery life is up to one year. This estimate was made on the
basis of 16 transmissions / hour to the DiCE SMART, which are equivalent
to the transmissions that would occur in a house lived all day.