Kemper 6541090 Manual Del Usuario página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

PLEASE READ CAREFULLY THE FOLLOWING SAFETY GUIDELINES BEFORE OPERATION AND
Installation and repair should be done by a qualified service person. Improper installation,
adjustment, alteration can cause personal injury or property damage.
Do not attempt to alter the unit in any manner.
Never replace or substitute the regulator with any regulator other than the factory-suggested
replacement.
Use a pressure reducer:
Do not store or use gasoline or other flammable vapours or liquids into the heater unit.
Do not transport heater while it's operating. Do not move the heater after it has been turned off until
the temperature has cooled down.
Keep the ventilation opening of the cylinder enclosure free and clear of debris.
Do not obstruct the ventilation holes of the gas cylinder seat.
Do not paint radiant screen, control panel or top canopy reflector.
Control compartment, burner and circulation air passage ways of the heater must be kept clean.
Frequent cleaning may be required as necessary.
The LP tank should be turned off when the heater is not in use.
Check the heater immediately if any of the following exist:
The heater does not reach temperature.
-
The burner makes popping noise during use (a slight noise is normal when the burner is
-
extinguished)
Smell of gas in conjunction with extreme yellow tipping of the burner flames.
-
The LP regulator/hose assembly must be located out of pathways where people may trip over or in
area where the hose will not subject to accidental damage.
Any guard or other protective device removed fro servicing the heater must be replaced before
operating the heater.
Adults and children should stay away from high temperature surface to avoid burns or clothing
ignition.
Children should be carefully supervised when they are in the area of the heater.
Clothing or other flammable materials should not be hung on the heater or placed on or near the
heater.
Check that the regulator seal is fitted and that it is in good conditions.
Always turn off completely your appliance each time you use it. Close the gas supply at the valve of
the gas cylinder or the regulator after use. Shut off the valve at the gas cylinder or the regulator
before moving the appliance.
HEATER STAND AND LOCATION
This heater is for use outdoor only and in well ventilated area.
A well ventilated area must have a minimum of 25% of the
surface area open. The surface area is the sum of the walls
surface
Always maintain proper clearance to combustible materials,
i.e. top 18" (50 cm) and sides 24" minimum (65 cm).
Heater must be placed on level firm ground.
Never operate heater in an explosive atmosphere like in
areas where gasoline or other flammable liquids or vapours
are stored.
In case of violent wind particular attention must be taken
against tilting of the appliance. We suggest to weigh down
the base or fix it to the floor with screws and in any case, to
remove the cap.
CAUTION
KEEP THE INSTRUCTION FOR FUTURE REFERENCE
gauged on 28 mbar for butane – gauged on 37 mbar for propane.
8/49

Publicidad

Tabla de contenido
loading

Tabla de contenido