3.2
REGULATION WITHOUT CONTROLLING EXTERNAL TEMPERATURE
The device heats continuously regardless the temperature of the room.
To turn on the device, plug in the power cord to a mains power outlet, and click the switch on the side. The switch led
flashes, the device is working.
The device starts heating in the continuous mode.
To switch off the device, disconnect the switch, the switch led turns off.
3.3 REGULATION
CONTROLLING EXTERNAL TEMPERATURE
The user can set the room temperature.
To turn on the device, plug in the power cord to a mains power outlet, and click the switch on the side. The switch
led flashes, the device is working.
The device starts heating in the continuous mode.
To select the room temperature, press the temperature button.
By pressing the temperature button for 2 seconds, all the lights turn off and the device keeps on working continuously, with no external temperature
regulation.
3.4 TIMER MODE
The device will work as long as the user sets up the time.
Press to select the operating time. By pressing repeatedly, operating working minutes are selected.
Once programmed time has elapsed, the device stops heating.
Eg. Deactivates in 60 minutes.
To deactivate the timer function, press until all lights are off.
4. TECHNICAL CHARACTERISTICS
Description:
Measures:
Weight:
Voltage
Frequency:
Plug:
Safety Thermostat:
Type of Protection:
Back Frame
Front
- Eco light on: 19 ºC
- Confort light on: 21 ºC
- Both lights on (Plus): 23 ºC
MEASURES & WEIGHT
STYLE 500 W Reversible
250 x 1000 x 40 (mm) Reversible
11 Kg.
TECHNICAL CHARACTERISTICS
230 V
50 Hz
Unipolar 10-15 A/250 VAC
Automatic – Cut-off Tª 90 ± 0,5º - Reset Tª 65º ± 10º
Class II IP 24
MATERIALS
High-quality Steel
DUAL KHERR
11