aUTO pOwEr OFF
1) After the test result is displayed on the screen for 10 seconds , the
symbol "OFF" appears on the display will turn off and the breathalyzer.
2) If the heating is interrupted or does not complete successfully, the
breathalyzer will go.
3) If, while in test mode, do not blow out for 10 seconds, the display will
show a result with all 0 and then turn off automatically.
NOTE
To get a result as reliable as possible, the manufacturer recommends
repeat the test two or three times.
rEplaCE ThE baTTErIEs
When the batteries are low, the screen flashes and we proceed its
replacement with new ones.
spECs
Sensor: Alcohol advanced semiconductor oxide . Range : 0.00-0.19
% BAC (blood alcohol concentration) & 0.0 to 1.9 g / l. Power: 2 x 1.5V
"AAA " alkaline batteries. Warm-up time : 10 seconds. Response time:
< 5 seconds. Dimensions: 95 x 36 x 18mm.
prECaUTIONs
After drinking is recommended to wait 20 minutes as this is the esti-
mated time for alcohol to be absorbed into the blood by organs and di-
gestive alcohol residue left in the mouth disappears about this time. For
best results, do not repeat the test at least twice within three minutes
from the last. Do not eat or smoke 20 minutes before testing. Do not use
chemicals to clean the device . Not blow the liquid inside the nozzle.
Do not use chemicals or the like near the breathalyzer , such as paints ,
pesticides, alcohol, etc. Do not store in breathalyzer in an enclosed and
air pollution. The result of this gives breathalyzer blood alcohol concen-
tration (BAC) for reference only. The manufacturer has no liability.
english
5