Sears Kenmore 407.53550 Manual De Uso página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

(7)
(8)
(9)
(4)
(5)
(2)
POWER ON/OFF (1)
Once the unit is plugged in, the POWER INDICA-
TOR (10) will light. Pressing the POWER button
once wilt turn the unit ON and illuminate the digi-
tal display (9). The fan will operate for 3 minutes
to draw air through the dehumidifier to properly
sense relative humidity. The display will show the
humidity level of the room in 5% increments,
down to a minimum of 25%. Pressing the Power
button again will turn the display OFF and the
unit will cease operating.
HUMIDITY LEVEL(2/3)
The humidity
level
can
be set in 5% incrementsin
a range from 35% to 80%. The humidity setting
is shown in the digital display. When the humidi-
ty level of the room reaches the set level, the
compressor will stop, but the fan will continue
operating for 3 minutes. To set the unit to continu-
ous operation, press the down arrow button until
the display shows 35%. Pressagain and the dis-
play will show CO. The Continuous indicator (13)
wilt light up on the control panel. To leave contin-
uous operation, pressthe UP arrow.
To check the current humidity setting, pressthe up
or down arrow. The display will show and set 5%
above or below the current settings.
FAN SPEED(5)
Press Fan
Speed
to toggle
between
Low, Med,
and High fan speeds. Speed will be shown in FAN
SPEEDINDICATOR (8)
BUCKET FULL INDICATOR
(11)
When the collection bucket is full, the BUCKET
FULL indicator (11) wilt light up and you wilt hear
an audible alarm. The audible alarm will last up
to ten seconds The dehumidifier will not run until
the bucket is removed, emptied and replaced.
(3)
(t)
(6)
DELAY START (4)
Unit can be programmed
to turn on at a desired
delay time by pressing the Timer (4) key. When
the unit is powered OFF, press the timer key once
for 2-hour delay start.
The 2 Hrs (7)
timer indica-
tor wilt light up when the timer key is pressed.
Press the timer key once more for a A-hour delay
start. The 4 Hrs (7) timer indicator
will now light
up. Press the timer key a third time to ctear the
timer setting. No timer indicators
will light up
when the timer setting is cleared.
AUTO SHUT-OFF (4)
Unit can be programmed to turn off at a desired
time by pressing the Timer (4) key. When the unit
is powered ON, press the timer key once for 2-
hour automatic shut-off. The 2 Hrs (7) timer indi-
cator will light up when the timer key is pressed.
Press the timer key once more for a 4-hour auto-
matic shut-off. The 4 Hrs (7} timer indicator will
now light up. Press the timer key a third time to
clear the timer setting. No timer indicators will
light up when the timer setting is cleared.
FILTERRESET(12)
The FILTERRESETindicator (12) will
light
up when
the filter needs cleaning. Remove the filter and
clean accordingly. Replace the filter when fin-
ished and pressand hold the FILTER(6) key up to
5 secondsto reset the filter indicator.
IMPORTANT:
Once the set humidity level is reached_ the
compressorwil! shutoff:. The fan will contin-
ue to run for up to 3 minutes.
Anytime the compressorstopsrunningfor
any reason, it will not restart for a minimum
of 3 minutes.Thisis a design feature to pro-
tect the compressorfrom damage.
6

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Kenmore 407.53570

Tabla de contenido