Installation Instructions – LAS Area / Site
SELECTABLE LUMEN SWITCH
Tools required:
5mm Allen Wrench, Torque Wrench, Small
Flat Head screwdriver (provided).
Ensure there is no power to the fixture prior to
N
ote:
adjusting the selectable lumen switch.
N
ote:
If for use with external controls system, follow
instructions below but remove dimming leads from
selectable lumen switch for use external to luminaire.
1.
Open the fixture door by loosening the three Allen head
screws. (Figure 1.) No need to completely remove the
Allen head screws, there is a rubber ring on each screw
to hold it to the housing door.
Figure 1.
2.
Using the provided small flat head screwdriver, adjust
the selectable lumen switch to the desired light level.
Nominal lumens in table below. For specific value by
optical distribution, refer to product specification sheet.
Switch Position
0 (Factory pre-set)
1
2
3
4
5
6
7
8
9
3.
Close and reinstall the door to the housing by
tightening the three Allen head screws to 30 in-lbs. Be
sure not to pinch any wires when closing the door.
2
COOPER LIGHTING SOLUTIONS
Allen
Head
Screws
LAS45
LAS100
20,000
34,000
18,400
31,100
16,800
28,400
14,500
24,500
13,400
22,600
12,000
20,400
11,500
19,500
10,700
18,100
4,900
8,300
4,900
8,300
IB514101EN
Installation instructions
INSTALLATION
Tools Required:
#2 Phillips screwdriver, 4/5/6mm Allen
wrenches, Torque Wrench, M15/M17 Socket Wrench, Drill
(optional).
1.
Remove the cover plate on the slipfitter mounting arm
via two Phillips head screws and set aside. (Figure 2.)
No need to completely remove the Phillips screws,
there is a rubber ring on each screw to hold it to the
cover plate.
Phillips Screw
Phillips Screw
Figure 2.
2.
Route wire leads from luminaire into the slipfitter and
install slipfitter onto luminaire. Secure with two allen
screws. Tighten to 30 in-lbs. (Figure 3.)
N
ote:
Be sure not to pinch wires between slipfitter and
luminaire.
Figure 3.
Allen
Head
Screws